Metadata: Identification_Information: Citation: Citation_Information: Originator: Katlin Bowman Adamczyk Originator: Amy Gartman Originator: Jaycee Favela Originator: Jacob Tidwell Publication_Date: 20250317 Title: Geochemistry of sediment subsamples from gravity cores and push cores from the Escanaba Trough (Gorda Ridge) Geospatial_Data_Presentation_Form: comma-delimited text Series_Information: Series_Name: data release Issue_Identification: DOI:10.5066/P13B46QX Publication_Information: Publication_Place: Pacific Coastal and Marine Science Center, Santa Cruz, California Publisher: U.S. Geological Survey Online_Linkage: https://doi.org/10.5066/P13B46QX Online_Linkage: https://www.sciencebase.gov/catalog/item/670957a2d34e969edc5a2a9b Larger_Work_Citation: Citation_Information: Originator: Katlin Bowman Adamczyk Originator: Amy Gartman Originator: Jaycee Favela Originator: Jacob Tidwell Publication_Date: 2025 Title: Computed tomography (CT) scans, photographs, geochemistry, grain-size analysis, X-ray fluorescence (XRF) scans, X-ray diffraction (XRD), magnetic susceptibility, and gamma-ray bulk density data of gravity cores and push cores from the Escanaba Trough (Gorda Ridge) Series_Information: Series_Name: data release Issue_Identification: DOI:10.5066/P13B46QX Publication_Information: Publication_Place: Pacific Coastal and Marine Science Center, Santa Cruz, CA Publisher: U.S. Geological Survey Other_Citation_Details: Suggested Citation: Adamczyk, K., Gartman, A., Favela, J., and Tidwell, J., 2025, Computed tomography (CT) scans, photographs, geochemistry, grain-size analysis, X-ray fluorescence (XRF) scans, X-ray diffraction (XRD), magnetic susceptibility, and gamma-ray bulk density data of gravity cores and push cores from the Escanaba Trough (Gorda Ridge): U.S. Geological Survey data release, https://doi.org/10.5066/P13B46QX. Online_Linkage: https://doi.org/10.5066/P13B46QX Online_Linkage: https://www.sciencebase.gov/catalog/item/67004442d34e80be174aea95 Description: Abstract: This portion of the data release contains geochemical data of sediment subsamples from push cores and gravity cores collected from the Escanaba Trough vent field, Gorda Ridge, in the northeast Pacific Ocean. These data were collected in 2022 (USGS Field Activity 2022-621-FA). Data include major, minor, and trace element concentrations, location information (latitude, longitude, depth), analytical methods, and instrument detection limits where available. Purpose: Data were obtained to characterize downcore geochemical properties of sediments. These data are intended for science researchers, students, policy makers, and the general public. Supplemental_Information: Additional information about the field activity or activities from which these data were derived is available online at: https://cmgds.marine.usgs.gov/fan_info.php?fan=2022-621-FA Any use of trade, product, or firm names is for descriptive purposes only and does not imply endorsement by the U.S. Government. Time_Period_of_Content: Time_Period_Information: Range_of_Dates/Times: Beginning_Date: 20220712 Ending_Date: 20231129 Currentness_Reference: Time data were compiled to completion of the last process step Status: Progress: Complete Maintenance_and_Update_Frequency: None planned Spatial_Domain: Bounding_Coordinates: West_Bounding_Coordinate: -127.5357 East_Bounding_Coordinate: -127.4076 North_Bounding_Coordinate: 41.1632 South_Bounding_Coordinate: 40.6957 Keywords: Theme: Theme_Keyword_Thesaurus: ISO 19115 Topic Category Theme_Keyword: oceans Theme_Keyword: geoscientificInformation Theme: Theme_Keyword_Thesaurus: Data Categories for Marine Planning Theme_Keyword: Nonliving Resources Theme_Keyword: Material Resources Theme_Keyword: Mineral Resources Theme_Keyword: Physical/Chemical Features Theme: Theme_Keyword_Thesaurus: USGS Thesaurus Theme_Keyword: push coring Theme_Keyword: gravity coring Theme_Keyword: chemical analysis Theme_Keyword: mass spectroscopy Theme_Keyword: geochemistry Theme_Keyword: metallic mineral resources Theme_Keyword: earth sciences Theme_Keyword: marine geology Theme: Theme_Keyword_Thesaurus: Marine Realms Information Bank (MRIB) keywords Theme_Keyword: sediment geochemistry Theme_Keyword: mineral resources Theme_Keyword: chemical analysis Theme: Theme_Keyword_Thesaurus: None Theme_Keyword: U.S. Geological Survey Theme_Keyword: USGS Theme_Keyword: Coastal and Marine Hazards and Resources Program Theme_Keyword: CMHRP Theme_Keyword: Pacific Coastal and Marine Science Center Theme_Keyword: PCMSC Theme_Keyword: Global Ocean Mineral Resources Theme: Theme_Keyword_Thesaurus: USGS Metadata Identifier Theme_Keyword: USGS:670957a2d34e969edc5a2a9b Place: Place_Keyword_Thesaurus: Geographic Names Information System (GNIS) Place_Keyword: Pacific Ocean Place: Place_Keyword_Thesaurus: NGA GEOnet Names Server (GNS) Place_Keyword: Escanaba Trough Place_Keyword: Gorda Ridge Access_Constraints: No access constraints Use_Constraints: USGS-authored or produced data and information are in the public domain from the U.S. Government and are freely redistributable with proper metadata and source attribution. Please recognize and acknowledge the U.S. Geological Survey as the originator of the dataset and in products derived from these data. Point_of_Contact: Contact_Information: Contact_Organization_Primary: Contact_Organization: U.S. Geological Survey, Pacific Coastal and Marine Science Center Contact_Person: PCMSC Science Data Coordinator Contact_Address: Address_Type: mailing and physical Address: 2885 Mission Street City: Santa Cruz State_or_Province: CA Postal_Code: 95060 Contact_Voice_Telephone: 831-427-4747 Contact_Electronic_Mail_Address: pcmsc_data@usgs.gov Browse_Graphic: Browse_Graphic_File_Name: https://www.sciencebase.gov/catalog/file/get/670957a2d34e969edc5a2a9b?name=geochemistry.jpg&allowOpen=true Browse_Graphic_File_Description: Push core sediment collection with a remotely operated vehicle. Browse_Graphic_File_Type: JPEG Data_Set_Credit: Exploring the Seafloor and Oceanic Footprints is an interagency effort involving the National Oceanic and Atmospheric Administration, the U.S. Geological Survey, and the Bureau of Ocean Energy Management. Funding is acknowledged from NOAA Ocean Exploration via its Ocean Exploration Fiscal Year 2019 Funding Opportunity and through the National Oceanographic Partnership Program (NOPP), from the USGS Coastal and Marine Hazards and Resources Enhanced Funding Opportunities, and from the Bureau of Ocean Energy Management through Interagency Agreement M19PG00021 with the United States Geological Survey. Native_Data_Set_Environment: Windows 11 Enterprise, Microsoft Excel 365 for enterprise Data_Quality_Information: Attribute_Accuracy: Attribute_Accuracy_Report: Certified reference materials, including PACS-3 (marine sediment certified by National Research Council Canada), were measured for all reported elements except Ag, B, Br, Cr, Ge, Ir, Lu, Na, Sc. The average relative percent difference (RPD) between measured and certified concentrations was 10–20 percent for Dy, Ta, Sr, Ni, Se, W, and Tm. Higher RPDs (>20 percent) were observed for Be and Hf. Average RPDs were <10 percent for Al, As, Au, Ba, Bi, Ca, Cd, Ce, Co, Cs, Cu, Er, Eu, Fe, Ga, Gd, Hg, Ho, In, K, La, Li, Mg, Mn, Mo, Nb, Nd, Pb, Pr, Rb, S, Sb, Si, Sm, Sn, Tb, Te, Th, Ti, Tl, U, V, Y, Yb, Zn, Zr. Duplicate measurements were made for all elements except Ag, B, Br, Cr, Ge, Ir, Lu, Na, and Sc. The average RPD between duplicate measurements was 10–20 percent for Dy, Ta, Sr, Ni, Se, W, Tm. Higher RPDs (>20 percent) were observed for Be and Hf. Average RPDs were <10 percent for Al, As, Au, Ba, Bi, Ca, Cd, Ce, Co, Cs, Cu, Er, Eu, Fe, Ga, Gd, Hg, Ho, In, K, La, Li, Mg, Mn, Mo, Nb, Nd, Pb, Pr, Rb, S, Sb, Si, Sm, Sn, Tb, Te, Th, Ti, Tl, U, V, Y, Yb, Zn, and Zr. The instruments and techniques used to generate the geochemical data are included in the data table and also summarized below in a Source Citation since data were generated by a commercial laboratory. Limits for each analyte's detection by an instrument are reported in the table. The value -8888 indicates that the measurement for an analyte was below the detection limit and the value -7777 indicates that the measurement for an analyte was above the detection limit. Logical_Consistency_Report: No formal logical accuracy tests were conducted. Completeness_Report: Dataset is considered complete for the information presented, as described in the abstract. Users are advised to read the rest of the metadata record carefully for additional details. Positional_Accuracy: Horizontal_Positional_Accuracy: Horizontal_Positional_Accuracy_Report: The locations of push core samples were determined using ROV Jason’s ultra-short baseline (USBL) navigation. Accuracy for this depth is approximately 6-26 m. The locations of gravity core samples were determined using the R/V Thomas G. Thompson’s GPS navigation, which is accurate to less than 5 m. A formal accuracy assessment of the horizontal positional information in the dataset has not been conducted. Vertical_Positional_Accuracy: Vertical_Positional_Accuracy_Report: For push core samples, the vertical accuracy was determined with ROV Jason’s altimeter, which is accurate to less than 1 m. For gravity core samples, the vertical accuracy was determined with the R/V Thomas G. Thompson’s multibeam bathymetry system. No formal positional accuracy tests were conducted. Lineage: Source_Information: Source_Citation: Citation_Information: Originator: Adamczyk, Katlin Originator: Gartman, Amy Originator: Favela, Jaycee Originator: Tidwell, Jacob Publication_Date: 2025 Title: Location and water depth for gravity cores and push cores from the Escanaba Trough (Gorda Ridge) Geospatial_Data_Presentation_Form: comma-delimited text Publication_Information: Publication_Place: online Publisher: U.S. Geological Survey Online_Linkage: https://www.sciencebase.gov/catalog/item/679282a3d34e88f5864c49e9 Type_of_Source_Media: U.S. Geological Survey data release Source_Time_Period_of_Content: Time_Period_Information: Range_of_Dates/Times: Beginning_Date: 20220524 Ending_Date: 20220613 Source_Currentness_Reference: ground condition at time samples were collected Source_Citation_Abbreviation: TN403_CoreLocations Source_Contribution: Latitude, longitude, and water depth information for gravity cores and push cores from this same data release Source_Information: Source_Citation: Citation_Information: Originator: Actlabs, Ancaster, Ontario, Canada Publication_Date: 2022 Title: Geochemical Element Analysis Online_Linkage: https://actlabs.com/geochemistry/ Type_of_Source_Media: geochemical analyses Source_Time_Period_of_Content: Time_Period_Information: Single_Date/Time: Calendar_Date: 20220712 Source_Currentness_Reference: Date that official lab reports were released by Actlabs Source_Citation_Abbreviation: geochemistry Source_Contribution: Geochemical analysis of sediment with Inductively Coupled Plasma Mass Spectrometry (sodium peroxide or lithium borate fusion), Instrumental Neutron Activation Analysis, and Cold Vapor Atomic Absorption Spectroscopy techniques. Process_Step: Process_Description: Push core and gravity core samples were collected on the R/V Thomas G. Thompson between May 24, 2022, and June 13, 2022, during the TN403 Escanaba Trough expedition, which was led and staffed by USGS employees. Push cores were pushed into sediment at 37 locations by ROV Jason’s manipulator arm in water depths between 3201 and 3301 meters. Gravity cores were collected using a gravity corer at 7 locations in water depths between 3209 and 3304 meters. Gravity cores greater than 60 cm in length were cut into sections onboard the ship and labeled ‘X’ (0-60 cm), ‘Y’ (60-120 cm), and ‘Z’ (>120 cm). All cores were stored upright and refrigerated until return to shore. Process_Date: 20220613 Process_Step: Process_Description: In the USGS Pacific Coastal and Marine Science Center (PCMSC) Core Preparation and Analysis Laboratory, subsamples were collected from relevant stratigraphic regions of the core. Pelagic clay and organic-rich sediments were air-dried and sulfidic sediments were dried in a glove bag purged with nitrogen gas. Dried sediment was ground to a powder using a mortar and pestle. Process_Date: 20220620 Process_Step: Process_Description: Approximately 10 grams of each sample was mailed to ACTLabs in individual plastic screw-top containers. All geochemical analyses were performed by ActLabs. Process_Date: 20220625 Process_Step: Process_Description: Results from lab analyses, detection limits, analytical method information, location data, cruise identification, and location data were combined into a comma-delimited text value document (TN403_SedimentGeochemistry.csv). Source_Used_Citation_Abbreviation: TN403_CoreLocations Source_Used_Citation_Abbreviation: geochemistry Process_Date: 20231129 Process_Contact: Contact_Information: Contact_Person_Primary: Contact_Person: Katlin Adamczyk Contact_Organization: USGS Contact_Position: Physical Scientist Contact_Address: Address_Type: mailing and physical Address: 2885 Mission Street City: Santa Cruz State_or_Province: CA Postal_Code: 95060 Contact_Voice_Telephone: 831-460-7420 Contact_Electronic_Mail_Address: kadamczyk@usgs.gov Spatial_Data_Organization_Information: Direct_Spatial_Reference_Method: Point Point_and_Vector_Object_Information: SDTS_Terms_Description: SDTS_Point_and_Vector_Object_Type: Point Point_and_Vector_Object_Count: 78 Spatial_Reference_Information: Horizontal_Coordinate_System_Definition: Geographic: Latitude_Resolution: 0.0001 Longitude_Resolution: 0.0001 Geographic_Coordinate_Units: Decimal degrees Geodetic_Model: Horizontal_Datum_Name: D_WGS_1984 Ellipsoid_Name: WGS_1984 Semi-major_Axis: 6378137.0 Denominator_of_Flattening_Ratio: 298.257222101 Entity_and_Attribute_Information: Detailed_Description: Entity_Type: Entity_Type_Label: TN403_SedimentGeochemistry.csv Entity_Type_Definition: Comma-delimited file containing results from geochemical analyses of marine sediment samples at the latitude, longitude, and water depth of each sample location. The value -8888 indicates that the measurement for an analyte was below the detection limit, and the value of -7777 indicates that the measurement for an analyte was above the detection limit. Entity_Type_Definition_Source: Producer defined Attribute: Attribute_Label: Cruise_ID Attribute_Definition: The alphanumeric cruise identifier for the expedition during which the sample was collected Attribute_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TN403 Enumerated_Domain_Value_Definition: Cruise identifier for the Escanaba Trough expedition onboard the R/V Thomas G. Thompson in 2022 Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sample_ID Attribute_Definition: The sample ID for each sample Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Sample IDs for gravity cores are formatted as GC#-section (for example, GC08-X is gravity core 08 section X). Gravity core sections are 'X' (0-60 cm), 'Y' (60-120 cm), and 'Z' (>120 cm). Sample IDs for push cores are formatted as Dive#-PushCore# (for example, J2-1418-PC03 is ROV Jason dive number J2-1418, push core number 03). Attribute: Attribute_Label: Subsample_Depth_Interval Attribute_Definition: The subsample depth interval for each sample Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: The depth interval, measured in centimeters from the top of the sediment-water interface in push cores and gravity core 'X' sections, or the top of the core liner for gravity core 'Y' and 'Z' sections. For example, GC06-Z-0–2 represents 0–2 cm in section Z of gravity core 06; 0 cm here is the top of section Z, not the sediment-water interface of the entire gravity core. Text appended after the sediment depth interval (such as _brown) are notable color descriptions of the material. Attribute: Attribute_Label: Latitude Attribute_Definition: Latitude at which sample was collected Attribute_Definition_Source: TN403_CoreLocations Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 40.6957 Range_Domain_Maximum: 41.1632 Attribute_Units_of_Measure: decimal degrees Attribute_Measurement_Resolution: .0001 Attribute: Attribute_Label: Longitude Attribute_Definition: Longitude at which sample was collected Attribute_Definition_Source: TN403_CoreLocations Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -127.5357 Range_Domain_Maximum: -127.4076 Attribute_Units_of_Measure: decimal degrees Attribute_Measurement_Resolution: .0001 Attribute: Attribute_Label: Water_Depth Attribute_Definition: Water depth in meters at which the sample was collected Attribute_Definition_Source: TN403_CoreLocations Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 3201 Range_Domain_Maximum: 3304 Attribute_Units_of_Measure: meters Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Fe Attribute_Definition: Iron concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 34300 Range_Domain_Maximum: 562000 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Mn Attribute_Definition: Manganese concentration in each sample. Values of -7777 indicate that the measurement was above the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 29 Range_Domain_Maximum: 34200 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Si Attribute_Definition: Silicon concentration in each sample. Values of -7777 indicate that the measurement was above the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1700 Range_Domain_Maximum: 305000 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Al Attribute_Definition: Aluminum concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 500 Range_Domain_Maximum: 87900 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Mg Attribute_Definition: Magnesium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 700 Range_Domain_Maximum: 84800 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Ca Attribute_Definition: Calcium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 300 Range_Domain_Maximum: 24400 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Na Attribute_Definition: Sodium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 3600 Range_Domain_Maximum: 38300 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: K Attribute_Definition: Potassium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 3000 Range_Domain_Maximum: 25000 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Ti Attribute_Definition: Titanium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 100 Range_Domain_Maximum: 4800 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: S Attribute_Definition: Sulfur concentration in each sample. Values of -7777 indicate that the measurement was above the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1100 Range_Domain_Maximum: 364000 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Ag Attribute_Definition: Silver concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry. Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 16 Range_Domain_Maximum: 35 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: As Attribute_Definition: Arsenic concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2.0 Range_Domain_Maximum: 5750.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: B Attribute_Definition: Boron concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 10 Range_Domain_Maximum: 300 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Ba Attribute_Definition: Barium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 500 Range_Domain_Maximum: 64800 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Be Attribute_Definition: Beryllium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Unrepresentable_Domain: Values of -8888 indicate that the measurement was below the detection limit (<3 ppm). Attribute: Attribute_Label: Bi Attribute_Definition: Bismuth concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2 Range_Domain_Maximum: 314 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Br Attribute_Definition: Bromine concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 24.5 Range_Domain_Maximum: 242.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Cd Attribute_Definition: Cadmium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2 Range_Domain_Maximum: 32 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Co Attribute_Definition: Cobalt concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 5 Range_Domain_Maximum: 981 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Cr Attribute_Definition: Chromium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 15 Range_Domain_Maximum: 209 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Cs Attribute_Definition: Caesium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .1 Range_Domain_Maximum: 10.2 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Cu Attribute_Definition: Copper concentration in each sample. Values of -7777 indicate that the measurement was above the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 23 Range_Domain_Maximum: 18400 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Ga Attribute_Definition: Gallium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 3.3 Range_Domain_Maximum: 38.9 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Ge Attribute_Definition: Germanium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .8 Range_Domain_Maximum: 43.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Hf Attribute_Definition: Hafnium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1 Range_Domain_Maximum: 6 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Hg Attribute_Definition: Mercury concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .026 Range_Domain_Maximum: 18.000 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .001 Attribute: Attribute_Label: In Attribute_Definition: Indium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .2 Range_Domain_Maximum: 15.3 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Li Attribute_Definition: Lithium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 16 Range_Domain_Maximum: 78 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Mo Attribute_Definition: Molybdenum concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 3 Range_Domain_Maximum: 152 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Nb Attribute_Definition: Niobium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2.4 Range_Domain_Maximum: 16.4 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Ni Attribute_Definition: Nickel concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 40 Range_Domain_Maximum: 340 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Pb Attribute_Definition: Lead concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 9.9 Range_Domain_Maximum: 3660.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Rb Attribute_Definition: Rubidium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1.1 Range_Domain_Maximum: 121.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Sb Attribute_Definition: Antimony concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .5 Range_Domain_Maximum: 206.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Sc Attribute_Definition: Scandium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .6 Range_Domain_Maximum: 19.9 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Se Attribute_Definition: Selenium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 8 Range_Domain_Maximum: 370 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Sn Attribute_Definition: Tin concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1.7 Range_Domain_Maximum: 291.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Sr Attribute_Definition: Strontium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 95 Range_Domain_Maximum: 1750 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Ta Attribute_Definition: Tantalum concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .2 Range_Domain_Maximum: 2.4 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Te Attribute_Definition: Tellurium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 7 Range_Domain_Maximum: 17 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Th Attribute_Definition: Thorium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .2 Range_Domain_Maximum: 11.1 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Tl Attribute_Definition: Thallium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .1 Range_Domain_Maximum: 14.7 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: U Attribute_Definition: Uranium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .9 Range_Domain_Maximum: 47.2 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: V Attribute_Definition: Vanadium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 24 Range_Domain_Maximum: 277 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: W Attribute_Definition: Tungsten concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .8 Range_Domain_Maximum: 6.7 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Zn Attribute_Definition: Zinc concentration in each sample. Values of -7777 indicate that the measurement was above the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 40 Range_Domain_Maximum: 10000 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Zr Attribute_Definition: Zirconium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2 Range_Domain_Maximum: 181 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: La Attribute_Definition: Lanthanum concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 3.6 Range_Domain_Maximum: 34.1 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Ce Attribute_Definition: Cerium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 4.9 Range_Domain_Maximum: 69.7 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Pr Attribute_Definition: Praseodymium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .4 Range_Domain_Maximum: 8.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Nd Attribute_Definition: Neodymium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1.7 Range_Domain_Maximum: 31.6 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Sm Attribute_Definition: Samarium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .4 Range_Domain_Maximum: 5.8 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Eu Attribute_Definition: Europium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .5 Range_Domain_Maximum: 17.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Gd Attribute_Definition: Gadolinium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .3 Range_Domain_Maximum: 6.2 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Tb Attribute_Definition: Terbium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .1 Range_Domain_Maximum: .8 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Dy Attribute_Definition: Dysprosium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .4 Range_Domain_Maximum: 4.8 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Y Attribute_Definition: Yttrium content in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .3 Range_Domain_Maximum: 25.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Ho Attribute_Definition: Holmium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .2 Range_Domain_Maximum: 1.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Er Attribute_Definition: Erbium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .1 Range_Domain_Maximum: 3.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Tm Attribute_Definition: Thulium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .1 Range_Domain_Maximum: .4 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Yb Attribute_Definition: Ytterbium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .1 Range_Domain_Maximum: 3.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .1 Attribute: Attribute_Label: Lu Attribute_Definition: Lutetium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .05 Range_Domain_Maximum: .41 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .01 Attribute: Attribute_Label: Au Attribute_Definition: Gold concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: .006 Range_Domain_Maximum: 3.060 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: .001 Attribute: Attribute_Label: Ir Attribute_Definition: Iridium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Unrepresentable_Domain: Values of -8888 indicate that the measurement was below the detection limit (<0.005 ppm). Attribute: Attribute_Label: Fe_Detection Attribute_Definition: The detection limit for iron concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 100 Range_Domain_Maximum: 500 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 100 Attribute: Attribute_Label: Mn_Detection Attribute_Definition: The detection limit for manganese concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 3 Range_Domain_Maximum: 100 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Si_Detection Attribute_Definition: The detection limit for silicon concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Al_Detection Attribute_Definition: The detection limit for aluminum concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Mg_Detection Attribute_Definition: The detection limit for magnesium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ca_Detection Attribute_Definition: The detection limit for calcium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Na_Detection Attribute_Definition: The detection limit for sodium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: K_Detection Attribute_Definition: The detection limit for potassium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ti_Detection Attribute_Definition: The detection limit for titanium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: S_Detection Attribute_Definition: The detection limit for sulfur concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ag_Detection Attribute_Definition: The detection limit for silver concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: As_Detection Attribute_Definition: The detection limit for arsenic concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: B_Detection Attribute_Definition: The detection limit for boron concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ba_Detection Attribute_Definition: The detection limit for barium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Be_Detection Attribute_Definition: The detection limit for beryllium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Bi_Detection Attribute_Definition: The detection limit for bismuth concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Br_Detection Attribute_Definition: The detection limit for bromine concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Cd_Detection Attribute_Definition: The detection limit for cadmium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Co_Detection Attribute_Definition: The detection limit for cobalt concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Cr_Detection Attribute_Definition: The detection limit for chromium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Cs_Detection Attribute_Definition: The detection limit for cesium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Cu_Detection Attribute_Definition: The detection limit for copper concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2 Range_Domain_Maximum: 50 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Ga_Detection Attribute_Definition: The detection limit for gallium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ge_Detection Attribute_Definition: The detection limit for germanium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Hf_Detection Attribute_Definition: The detection limit for hafnium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Hg_Detection Attribute_Definition: The detection limit for mercury concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: In_Detection Attribute_Definition: The detection limit for indium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Li_Detection Attribute_Definition: The detection limit for lithium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Mo_Detection Attribute_Definition: The detection limit for molybdenum concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Nb_Detection Attribute_Definition: The detection limit for niobium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ni_Detection Attribute_Definition: The detection limit for nickel concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Pb_Detection Attribute_Definition: The detection limit for lead concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Rb_Detection Attribute_Definition: The detection limit for rubidium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sb_Detection Attribute_Definition: The detection limit for antimony concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sc_Detection Attribute_Definition: The detection limit for scandium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Se_Detection Attribute_Definition: The detection limit for selenium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sn_Detection Attribute_Definition: The detection limit for tin concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sr_Detection Attribute_Definition: The detection limit for strontium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ta_Detection Attribute_Definition: The detection limit for tantalum concentration based on the measurement method and instrumentation. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Te_Detection Attribute_Definition: The detection limit for tellurium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Th_Detection Attribute_Definition: The detection limit for thorium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Tl_Detection Attribute_Definition: The detection limit for thallium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: U_Detection Attribute_Definition: The detection limit for uranium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: V_Detection Attribute_Definition: The detection limit for vanadium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: W_Detection Attribute_Definition: The detection limit for tungsten concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Zn_Detection Attribute_Definition: The detection limit for zinc concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Zr_Detection Attribute_Definition: The detection limit for zirconium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: La_Detection Attribute_Definition: The detection limit for lanthanum concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ce_Detection Attribute_Definition: The detection limit for cerium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Pr_Detection Attribute_Definition: The detection limit for praseodymium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Nd_Detection Attribute_Definition: The detection limit for neodymium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sm_Detection Attribute_Definition: The detection limit for samarium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Eu_Detection Attribute_Definition: The detection limit for europium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Gd_Detection Attribute_Definition: The detection limit for gadolinium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Tb_Detection Attribute_Definition: The detection limit for terbium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Dy_Detection Attribute_Definition: The detection limit for dysprosium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Y_Detection Attribute_Definition: The detection limit for yttrium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ho_Detection Attribute_Definition: The detection limit for holmium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Er_Detection Attribute_Definition: The detection limit for erbium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Tm_Detection Attribute_Definition: The detection limit for thulium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Yb_Detection Attribute_Definition: The detection limit for ytterbium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Lu_Detection Attribute_Definition: The detection limit for lutetium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Au_Detection Attribute_Definition: The detection limit for gold concentration based on the measurement method and instrumentation. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ir_Detection Attribute_Definition: The detection limit for iridium concentration based on the measurement method and instrumentation. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Fe_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure iron concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Mn_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure manganese concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_OES_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Optical Emission Spectroscopy sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Si_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure silicon concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Al_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure aluminum concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Mg_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure magnesium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ca_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure calcium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Na_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure sodium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: K_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure potassium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ti_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure titanium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: S_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure sulfur concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ag_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure silver concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: As_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure arsenic concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: B_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure boron concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ba_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure barium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Be_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure beryllium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Bi_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure bismuth concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Br_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure bromine concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Cd_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure cadmium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Co_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure cobalt concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Cr_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure chromium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Cs_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure caesium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Cu_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure copper concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_OES_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Optical Emission Spectroscopy sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ga_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure gallium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ge_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure germanium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Hf_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure hafnium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Hg_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure mercury concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: CVAAS Enumerated_Domain_Value_Definition: Cold Vapor Atomic Absorption Spectroscopy Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: In_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure indium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Li_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure lithium concentration based on the measurement method and instrumentation Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Mo_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure molybdenum concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Nb_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure niobium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ni_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure nickel concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Pb_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure lead concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Rb_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure rubidium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sb_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure antimony concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sc_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure scandium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Se_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure selenium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sn_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure tin concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sr_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure strontium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ta_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure tantalum concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Te_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure tellurium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Th_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure thorium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Tl_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure thallium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: U_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure uranium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: V_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure vanadium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: W_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure tungsten concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Zn_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure zinc concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Zr_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure zirconium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_FUS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, Lithium Borate Fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: La_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure lanthanum concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ce_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure cerium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Pr_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure praseodymium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Nd_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure neodymium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sm_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure samarium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Eu_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure europium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Gd_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure gadolinium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Tb_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure terbium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Dy_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure dysprosium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Y_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure yttrium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ho_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure holmium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Er_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure erbium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Tm_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure thulium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Yb_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure ytterbium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Lu_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure lutetium concentration Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Au_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure gold concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ir_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure iridium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis Enumerated_Domain_Value_Definition_Source: producer defined Overview_Description: Entity_and_Attribute_Overview: The first line of the csv file is a header line. Entity_and_Attribute_Detail_Citation: U.S. Geological Survey Distribution_Information: Distributor: Contact_Information: Contact_Organization_Primary: Contact_Organization: U.S. Geological Survey - ScienceBase Contact_Address: Address_Type: mailing and physical Address: Denver Federal Center, Building 810, Mail Stop 302 City: Denver State_or_Province: CO Postal_Code: 80225 Contact_Voice_Telephone: 1-888-275-8747 Contact_Electronic_Mail_Address: sciencebase@usgs.gov Resource_Description: These data are available in .csv format contained in a single file. Distribution_Liability: Unless otherwise stated, all data, metadata and related materials are considered to satisfy the quality standards relative to the purpose for which the data were collected. Although these data and associated metadata have been reviewed for accuracy and completeness and approved for release by the U.S. Geological Survey (USGS), no warranty expressed or implied is made regarding the display or utility of the data on any other system or for general or scientific purposes, nor shall the act of distribution constitute any such warranty. Standard_Order_Process: Digital_Form: Digital_Transfer_Information: Format_Name: comma-delimited text Format_Version_Number: Microsoft Excel 16.16.17 for Mac Format_Information_Content: File contains table in .csv format File_Decompression_Technique: No compression applied Transfer_Size: .099 Digital_Transfer_Option: Online_Option: Computer_Contact_Information: Network_Address: Network_Resource_Name: https://www.sciencebase.gov/catalog/file/get/670957a2d34e969edc5a2a9b Network_Resource_Name: https://www.sciencebase.gov/catalog/item/670957a2d34e969edc5a2a9b Network_Resource_Name: https://doi.org/10.5066/P13B46QX Access_Instructions: Data and metadata can be downloaded using the Network_Resource_Name links. The first link is a direct link to download a zipped file of data and metadata. The second link points to a landing page with metadata and data. The third link points to the landing page for the entire data release. Fees: None. Technical_Prerequisites: These data can be viewed with Microsoft Excel or any text reader. Metadata_Reference_Information: Metadata_Date: 20250317 Metadata_Contact: Contact_Information: Contact_Organization_Primary: Contact_Organization: U.S. Geological Survey, Pacific Coastal and Marine Science Center Contact_Person: PCMSC Science Data Coordinator Contact_Address: Address_Type: mailing and physical Address: 2885 Mission Street City: Santa Cruz State_or_Province: CA Postal_Code: 95060 Contact_Voice_Telephone: 831-427-4747 Contact_Electronic_Mail_Address: pcmsc_data@usgs.gov Metadata_Standard_Name: Content Standard for Digital Geospatial Metadata Metadata_Standard_Version: FGDC-STD-001-1998