Metadata: Identification_Information: Citation: Citation_Information: Originator: Amy Gartman Originator: Denise Payan Publication_Date: 20241120 Title: Major, minor, and trace element data for rock samples from Von Damm vent field, Mid-Cayman Rise Geospatial_Data_Presentation_Form: comma-delimited text Series_Information: Series_Name: data release Issue_Identification: DOI:10.5066/P14NQIHF Publication_Information: Publication_Place: Pacific Coastal and Marine Science Center, Santa Cruz, California Publisher: U.S. Geological Survey Online_Linkage: https://doi.org/10.5066/P14NQIHF Larger_Work_Citation: Citation_Information: Originator: Amy Gartman Originator: Denise Payan Publication_Date: 2024 Title: Major, minor and trace elements, carbon isotopes, Raman spectra, and X-ray diffractograms from Von Damm vent field, Mid-Cayman Rise Series_Information: Series_Name: data release Issue_Identification: DOI:10.5066/P14NQIHF Publication_Information: Publication_Place: Pacific Coastal and Marine Science Center, Santa Cruz, California Publisher: U.S. Geological Survey Other_Citation_Details: Suggested Citation: Gartman, A., Payan, D., 2024, Major, minor and trace elements, carbon isotopes, Raman spectra, and X-ray diffractograms from Von Damm vent field, Mid-Cayman Rise: U.S. Geological Survey data release, https://doi.org/10.5066/P14NQIHF. Online_Linkage: https://doi.org/10.5066/P14NQIHF Description: Abstract: This portion of the data release presents major, minor and trace element data of rock samples collected from Von Damm vent field, Mid Cayman Rise, in the Caribbean Sea. These data were collected in 2020 (USGS Field Activity 2020-602-FA). Purpose: These data serve to expand the knowledge and statistics for deep ocean marine mineral occurrences and composition within the global ocean. Supplemental_Information: Funding for this research is acknowledged from the U.S. Geological Survey Coastal and Marine Hazards and Resources Program, through the U.S. Geological Survey Pacific Coastal and Marine Science Center. Additional information about the USGS field activities from which these data were derived is available online at: https://cmgds.marine.usgs.gov/fan_info.php?fan=2020-602-FA Any use of trade, product, or firm names is for descriptive purposes only and does not imply endorsement by the U.S. Government. Time_Period_of_Content: Time_Period_Information: Range_of_Dates/Times: Beginning_Date: 20200114 Ending_Date: 20240725 Currentness_Reference: Date that the last process step was completed Status: Progress: Complete Maintenance_and_Update_Frequency: None planned Spatial_Domain: Bounding_Coordinates: West_Bounding_Coordinate: -81.735 East_Bounding_Coordinate: -81.089 North_Bounding_Coordinate: 18.83 South_Bounding_Coordinate: 17.747 Keywords: Theme: Theme_Keyword_Thesaurus: ISO 19115 Topic Category Theme_Keyword: oceans Theme_Keyword: geoscientificInformation Theme: Theme_Keyword_Thesaurus: Data Categories for Marine Planning Theme_Keyword: Nonliving Resources Theme_Keyword: Material Resources Theme_Keyword: Mineral Resources Theme_Keyword: Physical/Chemical Features Theme: Theme_Keyword_Thesaurus: USGS Thesaurus Theme_Keyword: ocean processes Theme_Keyword: ocean characteristics Theme_Keyword: geochemistry Theme_Keyword: metallic mineral resources Theme_Keyword: marine geology Theme: Theme_Keyword_Thesaurus: Marine Realms Information Bank (MRIB) keywords Theme_Keyword: sediment geochemistry Theme_Keyword: mineral resources Theme_Keyword: chemical analysis Theme: Theme_Keyword_Thesaurus: None Theme_Keyword: U.S. Geological Survey Theme_Keyword: USGS Theme_Keyword: Coastal and Marine Hazards and Resources Program Theme_Keyword: CMHRP Theme_Keyword: Pacific Coastal and Marine Science Center Theme_Keyword: PCMSC Theme_Keyword: Global Ocean Mineral Resources Theme_Keyword: mineralogical analysis Theme: Theme_Keyword_Thesaurus: USGS Metadata Identifier Theme_Keyword: USGS:6712961dd34eb6a152fc7109 Place: Place_Keyword_Thesaurus: NGA GEOnet Names Server (GNS) Place_Keyword: Caribbean Sea Place: Place_Keyword_Thesaurus: None Place_Keyword: Von Damm vent field Place_Keyword: Mid-Cayman Rise Access_Constraints: No access constraints Use_Constraints: USGS-authored or produced data and information are in the public domain from the U.S. Government and are freely redistributable with proper metadata and source attribution. Please recognize and acknowledge the U.S. Geological Survey as the originator of the dataset and in products derived from these data. Point_of_Contact: Contact_Information: Contact_Organization_Primary: Contact_Organization: U.S. Geological Survey, Pacific Coastal and Marine Science Center Contact_Person: PCMSC Science Data Coordinator Contact_Address: Address_Type: mailing and physical Address: 2885 Mission Street City: Santa Cruz State_or_Province: CA Postal_Code: 95060 Contact_Voice_Telephone: 831-427-4747 Contact_Electronic_Mail_Address: pcmsc_data@usgs.gov Native_Data_Set_Environment: Mac OSX 11.6.1, Microsoft Excel 16.47.1 for Mac Cross_Reference: Citation_Information: Originator: J.M. McDermott Originator: J.S. Seewald Originator: C.R. German Originator: S.P. Silva Publication_Date: 2015 Title: Pathways for abiotic organic synthesis at submarine hydrothermal fields Other_Citation_Details: McDermott, J. M., Seewald, J. S., German, C. R., & Sylva, S. P. (2015). Pathways for abiotic organic synthesis at submarine hydrothermal fields.�Proceedings of the National Academy of Sciences,�112(25), 7668-7672. This reference contains the original map and location names included in this dataset. Online_Linkage: https://doi.org/10.1073/pnas.1506295112 Data_Quality_Information: Attribute_Accuracy: Attribute_Accuracy_Report: All geochemistry data were calibrated against certified reference materials. The instruments and techniques used to generate the geochemical data are included in the data table. Limits for each analyte's detection by an instrument are reported in the table. The value -8888 indicates that the measurement for an analyte was below the detection limit. The value -7777 indicates that the value was above the technique limit. Values of -9999 for concentration attributes indicate that no analysis was performed. Values of NaN and -9999 for method and detection limit attributes respectively indicate that no information was available. For this dataset, the Certified Reference Material used include OREAS753, 680, 13b, all by Ore Research and Exploration Pty Ltd, and Mount Pleasant (MP)-2a, by Natural Resources Canada. Accuracy is better than 5 percent for all elements except for As, V, and Hg, for which accuracy was better than 10 percent, and Te, which was 10.7 percent. Logical_Consistency_Report: No formal logical accuracy tests were conducted. Completeness_Report: Dataset is considered complete for the information presented, as described in the abstract. Users are advised to read the rest of the metadata record carefully for additional details. Positional_Accuracy: Horizontal_Positional_Accuracy: Horizontal_Positional_Accuracy_Report: The horizontal accuracy for each sample was obtained from the ROV's Ultra Short Baseline Positioning System (USBL) navigation after calibration to the CASIUS (Calibration of Attitude Sensors In USBL Systems) calibration system. Accuracy for this depth is approximately 10- 20 m. Vertical_Positional_Accuracy: Vertical_Positional_Accuracy_Report: The vertical accuracy was determined using multiple DVLs (Doppler Velocity Loggers) on the ROV, which are accurate to less than 1 m. Lineage: Process_Step: Process_Description: Samples are rocks and were collected by the ROV's manipulator arm. Once recovered shipboard photographed and returned to shore. Amy Gartman attended 2020-602-FA, cruise name AT42-22. Process_Date: 20200206 Process_Step: Process_Description: At USGS, bulk samples and subsamples were collected from relevant regions of the rocks. Process_Date: 20200801 Source_Produced_Citation_Abbreviation: samples Process_Step: Process_Description: Subsamples were powdered using a shatterbox and powders were mailed to SGS Laboratories, Lakefield, Ontario, Canada. Source_Used_Citation_Abbreviation: samples Process_Date: 20200901 Source_Produced_Citation_Abbreviation: results Process_Step: Process_Description: Results from the major, minor and trace element datasets were combined into a comma-delimited text values document (VonDamm_geochemistry_rawdata.csv). Source_Used_Citation_Abbreviation: results Process_Date: 20240725 Spatial_Data_Organization_Information: Direct_Spatial_Reference_Method: Point Point_and_Vector_Object_Information: SDTS_Terms_Description: SDTS_Point_and_Vector_Object_Type: Point Point_and_Vector_Object_Count: 11 Spatial_Reference_Information: Horizontal_Coordinate_System_Definition: Geographic: Latitude_Resolution: 0.0000001 Longitude_Resolution: 0.0000001 Geographic_Coordinate_Units: Decimal degrees Geodetic_Model: Horizontal_Datum_Name: D_WGS_1984 Ellipsoid_Name: WGS_1984 Semi-major_Axis: 6378137.0 Denominator_of_Flattening_Ratio: 298.257222101 Entity_and_Attribute_Information: Detailed_Description: Entity_Type: Entity_Type_Label: VonDamm_geochemistry_rawdata.csv Entity_Type_Definition: Comma-delimited file containing results from major, minor and trace element analyses of rock samples. Entity_Type_Definition_Source: Producer defined Attribute: Attribute_Label: Cruise_ID Attribute_Definition: Lists the alphanumeric cruise identifier for the expedition during which the sample was collected Attribute_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: AT42-22 Enumerated_Domain_Value_Definition: IMR cruise identification affiliated with Field Activity 2020-602-FA Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sample_ID Attribute_Definition: The sample ID for each sample Attribute_Definition_Source: producer defined Attribute_Domain_Values: Unrepresentable_Domain: The sample names include a dive number (ROV, denoting remotely operated vehicle, followed by a number) and rock number (R, denoting rock, followed by a number). Attribute: Attribute_Label: Latitude Attribute_Definition: Latitude at which sample was collected Attribute_Definition_Source: producer defined Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 18.3747419 Range_Domain_Maximum: 18.3763850 Attribute_Units_of_Measure: decimal degrees Attribute_Measurement_Resolution: 0.0000001 Attribute: Attribute_Label: Longitude Attribute_Definition: Longitude at which sample was collected Attribute_Definition_Source: producer defined Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -81.7980902 Range_Domain_Maximum: -81.7971780 Attribute_Units_of_Measure: decimal degrees Attribute_Measurement_Resolution: 0.0000001 Attribute: Attribute_Label: Water_Depth Attribute_Definition: Water depth in meters at which the sample was collected. Attribute_Definition_Source: producer defined Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2360 Range_Domain_Maximum: 2388 Attribute_Units_of_Measure: meters (m) Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Sublocation name Attribute_Definition: Specific location within the vent field where sample was collected Attribute_Definition_Source: producer defined Attribute_Domain_Values: Unrepresentable_Domain: Locations within the vent field were previously named in McDermott, J. M., Seewald, J. S., German, C. R., & Sylva, S. P. (2015). Pathways for abiotic organic synthesis at submarine hydrothermal fields.�Proceedings of the National Academy of Sciences,�112(25), 7668-7672. Attribute: Attribute_Label: Fe Attribute_Definition: Iron concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1888 Range_Domain_Maximum: 11749 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Mn Attribute_Definition: Manganese concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 107 Range_Domain_Maximum: 1346 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Si Attribute_Definition: Silicon concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 138520 Range_Domain_Maximum: 304716 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Al Attribute_Definition: Aluminum concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 158 Range_Domain_Maximum: 3545 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Mg Attribute_Definition: Magnesium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 139151 Range_Domain_Maximum: 172024 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Ca Attribute_Definition: Calcium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 429 Range_Domain_Maximum: 98128 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Na Attribute_Definition: Sodium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2003 Range_Domain_Maximum: 7122 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: K Attribute_Definition: Potassium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 332 Range_Domain_Maximum: 1079 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Ti Attribute_Definition: Titanium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: P Attribute_Definition: Phosphorus concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 43 Range_Domain_Maximum: 436 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: S Attribute_Definition: Sulfur concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 170 Range_Domain_Maximum: 6440 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 10 Attribute: Attribute_Label: Ag Attribute_Definition: Silver concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.05 Range_Domain_Maximum: 76.93 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: As Attribute_Definition: Arsenic concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2 Range_Domain_Maximum: 25 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: B Attribute_Definition: Boron concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Ba Attribute_Definition: Barium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1 Range_Domain_Maximum: 13 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Be Attribute_Definition: Berrylium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.1 Range_Domain_Maximum: 0.3 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Bi Attribute_Definition: Bismuth concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Br Attribute_Definition: Bromine concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Cd Attribute_Definition: Cadmium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.04 Range_Domain_Maximum: 2.36 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Cl Attribute_Definition: Chlorine concentration in each sample. Values of -7777 indicate that the value was above the technique limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1962 Range_Domain_Maximum: 4782 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Co Attribute_Definition: Cobalt concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.2 Range_Domain_Maximum: 21.9 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Cr Attribute_Definition: Chromium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2 Range_Domain_Maximum: 11 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Cs Attribute_Definition: Cesium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.1 Range_Domain_Maximum: 0.2 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Cu Attribute_Definition: Copper concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 95.2 Range_Domain_Maximum: 6436.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: F Attribute_Definition: Fluorine concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1172 Range_Domain_Maximum: 3346 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Ga Attribute_Definition: Gallium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 3.9 Range_Domain_Maximum: 38.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Ge Attribute_Definition: Germanium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1 Range_Domain_Maximum: 3 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Hf Attribute_Definition: Hafnium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Hg Attribute_Definition: Mercury concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.135 Range_Domain_Maximum: 1.232 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.001 Attribute: Attribute_Label: In Attribute_Definition: Indium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Li Attribute_Definition: Lithium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 22 Range_Domain_Maximum: 134 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Mo Attribute_Definition: Molybdenum concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.24 Range_Domain_Maximum: 10.05 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Nb Attribute_Definition: Niobium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Ni Attribute_Definition: Nickel concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2 Range_Domain_Maximum: 25 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Pb Attribute_Definition: Lead concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.6 Range_Domain_Maximum: 117.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Rb Attribute_Definition: Rubidium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.4 Range_Domain_Maximum: 3.5 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Sb Attribute_Definition: Antimony concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.15 Range_Domain_Maximum: 26.90 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Sc Attribute_Definition: Scandium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Se Attribute_Definition: Selenium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Sn Attribute_Definition: Tin concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Sr Attribute_Definition: Strontium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 6.8 Range_Domain_Maximum: 208.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Ta Attribute_Definition: Tantalum concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Te Attribute_Definition: Tellurium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.11 Range_Domain_Maximum: 6.87 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Th Attribute_Definition: Thorium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Tl Attribute_Definition: Thallium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.04 Range_Domain_Maximum: 21.69 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: U Attribute_Definition: Uranium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 7.33 Range_Domain_Maximum: 62.99 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: V Attribute_Definition: Vanadium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 13 Range_Domain_Maximum: 50 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: W Attribute_Definition: Tungsten concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.2 Range_Domain_Maximum: 1.6 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Zn Attribute_Definition: Zinc concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 12 Range_Domain_Maximum: 443 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Zr Attribute_Definition: Zirconium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.6 Range_Domain_Maximum: 8.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: La Attribute_Definition: Lanthanum concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.1 Range_Domain_Maximum: 1.9 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Ce Attribute_Definition: Cerium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.2 Range_Domain_Maximum: 8.7 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Pr Attribute_Definition: Praseodymium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.07 Range_Domain_Maximum: 0.49 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Nd Attribute_Definition: Neodyium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.1 Range_Domain_Maximum: 1.9 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Sm Attribute_Definition: Samarium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.2 Range_Domain_Maximum: 0.6 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Eu Attribute_Definition: Europium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.15 Range_Domain_Maximum: 2.29 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Gd Attribute_Definition: Gadolinium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.07 Range_Domain_Maximum: 0.51 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Tb Attribute_Definition: Terbium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Dy Attribute_Definition: Dysprosium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.07 Range_Domain_Maximum: 0.40 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Y Attribute_Definition: Yttrium content in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.2 Range_Domain_Maximum: 2.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Ho Attribute_Definition: Holmium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Er Attribute_Definition: Erbium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.05 Range_Domain_Maximum: 0.25 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Tm Attribute_Definition: Thulium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Yb Attribute_Definition: Ytterbium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -9999 Range_Domain_Maximum: -9999 Attribute_Units_of_Measure: parts per million Attribute: Attribute_Label: Lu Attribute_Definition: Lutetium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.01 Range_Domain_Maximum: 0.04 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Au Attribute_Definition: Gold concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.0017 Range_Domain_Maximum: 0.6855 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.0001 Attribute: Attribute_Label: TOC Attribute_Definition: Total organic carbon concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 769 Range_Domain_Maximum: 15950 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: TIC Attribute_Definition: Total inorganic carbon concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 11 Range_Domain_Maximum: 53748 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Fe_Detection Attribute_Definition: The detection limit for iron concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Mn_Detection Attribute_Definition: The detection limit for manganese concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Si_Detection Attribute_Definition: The detection limit for silicon concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Al_Detection Attribute_Definition: The detection limit for aluminum concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Mg_Detection Attribute_Definition: The detection limit for magnesium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ca_Detection Attribute_Definition: The detection limit for calcium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Na_Detection Attribute_Definition: The detection limit for sodium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: K_Detection Attribute_Definition: The detection limit for potassium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ti_Detection Attribute_Definition: The detection limit for titanium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: P_Detection Attribute_Definition: The detection limit for phosphorus concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: S_Detection Attribute_Definition: The detection limit for sulfur concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ag_Detection Attribute_Definition: The detection limit for silver concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: As_Detection Attribute_Definition: The detection limit for arsenic concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: B_Detection Attribute_Definition: The detection limit for boron concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ba_Detection Attribute_Definition: The detection limit for barium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Be_Detection Attribute_Definition: The detection limit for beryllium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Bi_Detection Attribute_Definition: The detection limit for bismuth concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Br_Detection Attribute_Definition: The detection limit for bromine concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Cd_Detection Attribute_Definition: The detection limit for cadmium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Cl_Detection Attribute_Definition: The detection limit for chlorine concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Co_Detection Attribute_Definition: The detection limit for cobalt concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Cr_Detection Attribute_Definition: The detection limit for chromium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Cs_Detection Attribute_Definition: The detection limit for cesium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Cu_Detection Attribute_Definition: The detection limit for copper concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: F_Detection Attribute_Definition: The detection limit for fluorine concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ga_Detection Attribute_Definition: The detection limit for gallium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ge_Detection Attribute_Definition: The detection limit for germanium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Hf_Detection Attribute_Definition: The detection limit for hafnium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Hg_Detection Attribute_Definition: The detection limit for mercury concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: In_Detection Attribute_Definition: The detection limit for indium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Li_Detection Attribute_Definition: The detection limit for lithium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Mo_Detection Attribute_Definition: The detection limit for molybdenum concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Nb_Detection Attribute_Definition: The detection limit for niobium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ni_Detection Attribute_Definition: The detection limit for nickel concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Pb_Detection Attribute_Definition: The detection limit for lead concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Rb_Detection Attribute_Definition: The detection limit for rubidium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sb_Detection Attribute_Definition: The detection limit for antimony concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sc_Detection Attribute_Definition: The detection limit for scandium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Se_Detection Attribute_Definition: The detection limit for selenium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sn_Detection Attribute_Definition: The detection limit for tin concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sr_Detection Attribute_Definition: The detection limit for strontium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ta_Detection Attribute_Definition: The detection limit for tantalum concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Te_Detection Attribute_Definition: The detection limit for tellurium concentration based on the measurement method and instrumentation. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Th_Detection Attribute_Definition: The detection limit for thorium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Tl_Detection Attribute_Definition: The detection limit for thallium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: U_Detection Attribute_Definition: The detection limit for uranium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: V_Detection Attribute_Definition: The detection limit for vanadium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: W_Detection Attribute_Definition: The detection limit for tungsten concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Zn_Detection Attribute_Definition: The detection limit for zinc concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Zr_Detection Attribute_Definition: The detection limit for zirconium concentration based on the measurement method and instrumentation. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: La_Detection Attribute_Definition: The detection limit for lanthanum concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ce_Detection Attribute_Definition: The detection limit for cerium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Pr_Detection Attribute_Definition: The detection limit for praseodymium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Nd_Detection Attribute_Definition: The detection limit for neodymium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sm_Detection Attribute_Definition: The detection limit for samarium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Eu_Detection Attribute_Definition: The detection limit for europium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Gd_Detection Attribute_Definition: The detection limit for gadolinium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Tb_Detection Attribute_Definition: The detection limit for terbium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Dy_Detection Attribute_Definition: The detection limit for dysprosium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Y_Detection Attribute_Definition: The detection limit for yttrium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ho_Detection Attribute_Definition: The detection limit for holmium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Er_Detection Attribute_Definition: The detection limit for erbium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Tm_Detection Attribute_Definition: The detection limit for thulium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Yb_Detection Attribute_Definition: The detection limit for ytterbium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Lu_Detection Attribute_Definition: The detection limit for lutetium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Au_Detection Attribute_Definition: The detection limit for gold concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: TOC_Detection Attribute_Definition: The detection limit for total organic carbon concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: TIC_Detection Attribute_Definition: The detection limit for total inorganic carbon concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Fe_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure iron concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: XRF_BF2 Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Mn_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure manganese concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Si_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure silicon concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: XRF_BF2 Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Al_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure aluminum concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: XRF_BF2 Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Mg_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure magnesium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: XRF_BF2 Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ca_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure calcium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: XRF_BF2 Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Na_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure sodium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: XRF_BF2 Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: K_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure potassium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: XRF_BF2 Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ti_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure titanium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NaN Enumerated_Domain_Value_Definition: method information not available Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: P_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure phosphorus concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: XRF_BF2 Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: S_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure sulfur concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: IR Enumerated_Domain_Value_Definition: IR Combustion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ag_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure silver concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP-OES_4ACID Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: As_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure arsenic concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_AR Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: B_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure boron concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NaN Enumerated_Domain_Value_Definition: Method information not available Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ba_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure barium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP-OES_4ACID Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Be_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure beryllium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_AR Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Bi_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure bismuth concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NaN Enumerated_Domain_Value_Definition: Method information was not available Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Br_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure bromine concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NaN Enumerated_Domain_Value_Definition: Method information was not available Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Cd_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure cadmium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_AR Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Cl_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure chlorine concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ISE Enumerated_Domain_Value_Definition: Ion Selective Electrode Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Co_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure cobalt concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_AR Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Cr_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure chromium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP-OES_4ACID Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Cs_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure cesium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Cu_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure copper concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP-OES_4ACID Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: F_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure flourine concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ISE Enumerated_Domain_Value_Definition: Ion Selective Electrode Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ga_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure gallium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_AR Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ge_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure germanium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Hf_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure hafnium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NaN Enumerated_Domain_Value_Definition: Method information not available Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Hg_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure mercury concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: CVAAS Enumerated_Domain_Value_Definition: Cold Vapor Atomic Absorption Spectroscopy Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: In_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure indium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NaN Enumerated_Domain_Value_Definition: Method information not available Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Li_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure lithium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP-OES_4ACID Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Mo_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure molybdenum concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_AR Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Nb_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure niobium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NaN Enumerated_Domain_Value_Definition: Method information not available Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ni_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure nickel concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP-OES_4ACID Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Pb_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure lead concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_AR Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Rb_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure rubidium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_AR Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sb_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure antimony concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_AR Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sc_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure scandium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NaN Enumerated_Domain_Value_Definition: Method information not available Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Se_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure selenium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NaN Enumerated_Domain_Value_Definition: Method information not available Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sn_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure tin concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NaN Enumerated_Domain_Value_Definition: Method information not available Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sr_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure strontium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP-OES_4ACID Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ta_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure tantalum concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NaN Enumerated_Domain_Value_Definition: Method information not available Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Te_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure tellurium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_AR Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Th_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure thorium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NaN Enumerated_Domain_Value_Definition: Method information not available Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Tl_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure thallium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_AR Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: U_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure uranium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_AR Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: V_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure vanadium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP-OES_4ACID Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: W_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure tungsten concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_AR Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Zn_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure zinc concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP-OES_4ACID Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Zr_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure zirconium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_HNO3_LiMB Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, lithium metaborate fusion followed by nitric acid digestion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: La_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure lanthanum concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ce_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure cerium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Pr_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure praseodymium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Nd_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure neodymium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sm_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure samarium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Eu_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure europium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Gd_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure gadolinium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Tb_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure terbium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Dy_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure dysprosium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Y_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure yttrium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ho_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure holmium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Er_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure erbium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Tm_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure thulium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Yb_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure ytterbium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Lu_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure lutetium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_Na2O2 Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Au_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure gold concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: ICP_MS_NiS_FA Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, nickel sulfide fire assay Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: TOC_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure total organic carbon concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: Wt_difference Enumerated_Domain_Value_Definition: Sample weight difference Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: TIC_method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure total inorganic carbon concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: UIC Enumerated_Domain_Value_Definition: UIC CM5230 acid digester attached to a CM5017 coulometer Enumerated_Domain_Value_Definition_Source: producer defined Overview_Description: Entity_and_Attribute_Overview: The first line of the csv file is a header line. Entity_and_Attribute_Detail_Citation: U.S. Geological Survey Distribution_Information: Distributor: Contact_Information: Contact_Organization_Primary: Contact_Organization: U.S. Geological Survey - ScienceBase Contact_Address: Address_Type: mailing and physical Address: Denver Federal Center, Building 810, Mail Stop 302 City: Denver State_or_Province: CO Postal_Code: 80225 Contact_Voice_Telephone: 1-888-275-8747 Contact_Electronic_Mail_Address: sciencebase@usgs.gov Resource_Description: These data are available in .csv format contained in a single file. Distribution_Liability: Unless otherwise stated, all data, metadata and related materials are considered to satisfy the quality standards relative to the purpose for which the data were collected. Although these data and associated metadata have been reviewed for accuracy and completeness and approved for release by the U.S. Geological Survey (USGS), no warranty expressed or implied is made regarding the display or utility of the data on any other system or for general or scientific purposes, nor shall the act of distribution constitute any such warranty. Standard_Order_Process: Digital_Form: Digital_Transfer_Information: Format_Name: comma-delimited text Format_Version_Number: Microsoft Excel 16.16.17 for Mac Format_Information_Content: File contains table in .csv format File_Decompression_Technique: No compression applied Transfer_Size: 0.2138 Digital_Transfer_Option: Online_Option: Computer_Contact_Information: Network_Address: Network_Resource_Name: https://www.sciencebase.gov/catalog/file/get/6712961dd34eb6a152fc7109 Network_Resource_Name: https://www.sciencebase.gov/catalog/item/6712961dd34eb6a152fc7109 Network_Resource_Name: https://doi.org/10.5066/P14NQIHF Access_Instructions: Data can be downloaded using the Network_Resource_Name links. The first link is a direct link to download a zipped file of data and metadata. The second link points to a landing page with metadata and data. The third link points to the landing page for the entire data release. Fees: None. Technical_Prerequisites: These data can be viewed with Microsoft Excel or any text reader. Metadata_Reference_Information: Metadata_Date: 20241120 Metadata_Contact: Contact_Information: Contact_Organization_Primary: Contact_Organization: U.S. Geological Survey, Pacific Coastal and Marine Science Center Contact_Person: PCMSC Science Data Coordinator Contact_Address: Address_Type: mailing and physical Address: 2885 Mission Street City: Santa Cruz State_or_Province: CA Postal_Code: 95060 Contact_Voice_Telephone: 831-427-4747 Contact_Electronic_Mail_Address: pcmsc_data@usgs.gov Metadata_Standard_Name: Content Standard for Digital Geospatial Metadata Metadata_Standard_Version: FGDC-STD-001-1998