Metadata: Identification_Information: Citation: Citation_Information: Originator: Jaycee Favela Originator: Kira Mizell Originator: Katlin Adamczyk Originator: Amy Gartman Publication_Date: 20241219 Title: Geochemical composition of ferromanganese crusts, nodules, and coated cobbles from seamounts in the Papahanaumokuakea Marine National Monument Geospatial_Data_Presentation_Form: comma-delimited text Series_Information: Series_Name: data release Issue_Identification: DOI:10.5066/P1WYF9T7 Publication_Information: Publication_Place: Pacific Coastal and Marine Science Center, Santa Cruz, California Publisher: U.S. Geological Survey Online_Linkage: https://doi.org/10.5066/P1WYF9T7 Larger_Work_Citation: Citation_Information: Originator: Jaycee Favela Originator: Kira Mizell Originator: Katlin Adamczyk Originator: Amy Gartman Publication_Date: 2024 Title: Geochemical composition and X-ray diffraction data (XRD) of ferromanganese crusts, nodules, and coated cobbles from seamounts in the Papahanaumokuakea Marine National Monument Series_Information: Series_Name: data release Issue_Identification: DOI:10.5066/P1WYF9T7 Publication_Information: Publication_Place: Pacific Coastal and Marine Science Center, Santa Cruz, California Publisher: U.S. Geological Survey Online_Linkage: https://doi.org/10.5066/P1WYF9T7 Description: Abstract: This portion of the data release provides geochemical analyses data of ferromanganese rock samples collected off the coast of Hawaii. Ferromanganese crusts, nodules, and coated cobbles were collected via ROV from seamounts within the Papahanaumokuakea Marine National Monument (PMNM) in the Pacific Ocean during E/V Nautilus expeditions NA134 and NA138 in 2021 and 2022, respectively. Ferromanganese rock samples were sent to USGS for subsampling and major and trace element geochemical analyses. Major and trace element data as well as location information (latitude, longitude, depth) for each sample are provided here. Purpose: These data serve to expand the knowledge and statistics for deep ocean marine mineral occurrences and composition within the global ocean. Supplemental_Information: We acknowledge funding from the USGS Coastal and Marine Hazards and Resources program through the USGS Pacific Coastal and Marine Science Center. This work was funded in part by the U.S. Department of the Interior, Bureau of Ocean Energy Management through Interagency Agreement M22PG00026 with the USGS. Sample collection was enabled by a grant from NOAA Ocean Exploration (NA21OAR0110199) to Beth Orcutt and supported by operational funds to the Ocean Exploration Trust by NOAA funding of the Ocean Exploration Cooperative Institute (NA19OAR4320072). The research within the Papahanaumokuakea Marine National Monument was permitted by the US Fish and Wildlife Service of the Department of the Interior (PMNM-2021-021) in consultation with the Office of Hawaiian Affairs and the Papahanaumokuakea Native Hawaiian Cultural Working Group. Any use of trade, product, or firm names is for descriptive purposes only and does not imply endorsement by the U.S. Government. Time_Period_of_Content: Time_Period_Information: Range_of_Dates/Times: Beginning_Date: 20211115 Ending_Date: 20240809 Currentness_Reference: Date that the samples were collected through last process step was completed Status: Progress: Complete Maintenance_and_Update_Frequency: None planned Spatial_Domain: Bounding_Coordinates: West_Bounding_Coordinate: -175.8771 East_Bounding_Coordinate: -170.9241 North_Bounding_Coordinate: 33.0537 South_Bounding_Coordinate: 22.1009 Keywords: Theme: Theme_Keyword_Thesaurus: ISO 19115 Topic Category Theme_Keyword: oceans Theme_Keyword: geoscientificInformation Theme: Theme_Keyword_Thesaurus: Data Categories for Marine Planning Theme_Keyword: Nonliving Resources Theme_Keyword: Material Resources Theme_Keyword: Mineral Resources Theme_Keyword: Physical/Chemical Features Theme_Keyword: Assessments Theme: Theme_Keyword_Thesaurus: USGS Thesaurus Theme_Keyword: dredge sampling Theme_Keyword: chemical analysis Theme_Keyword: mass spectroscopy Theme_Keyword: geochemistry Theme_Keyword: metallic mineral resources Theme: Theme_Keyword_Thesaurus: Marine Realms Information Bank (MRIB) keywords Theme_Keyword: sediment geochemistry Theme_Keyword: chemical analysis Theme: Theme_Keyword_Thesaurus: None Theme_Keyword: U.S. Geological Survey Theme_Keyword: USGS Theme_Keyword: Coastal and Marine Hazards and Resources Program Theme_Keyword: CMHRP Theme_Keyword: Pacific Coastal and Marine Science Center Theme_Keyword: PCMSC Theme_Keyword: Global Ocean Mineral Resources Theme: Theme_Keyword_Thesaurus: USGS Metadata Identifier Theme_Keyword: USGS:66bbe310d34e033882817489 Place: Place_Keyword_Thesaurus: Geographic Names Information System (GNIS) Place_Keyword: Pacific Ocean Place_Keyword: State of Hawaii Place: Place_Keyword_Thesaurus: None Place_Keyword: Papahanaumokuakea Marine National Monument Access_Constraints: No access constraints Use_Constraints: USGS-authored or produced data and information are in the public domain from the U.S. Government and are freely redistributable with proper metadata and source attribution. Please recognize and acknowledge the U.S. Geological Survey as the originator of the dataset and in products derived from these data. Point_of_Contact: Contact_Information: Contact_Organization_Primary: Contact_Organization: U.S. Geological Survey, Pacific Coastal and Marine Science Center Contact_Person: PCMSC Science Data Coordinator Contact_Address: Address_Type: mailing and physical Address: 2885 Mission Street City: Santa Cruz State_or_Province: CA Postal_Code: 95060 Contact_Voice_Telephone: 831-427-4747 Contact_Electronic_Mail_Address: pcmsc_data@usgs.gov Native_Data_Set_Environment: Mac OSX 11.6.1, Microsoft Excel 16.47.1 for Mac Data_Quality_Information: Attribute_Accuracy: Attribute_Accuracy_Report: All geochemistry data were calibrated against certified reference materials. The instruments and techniques used to generate the geochemical data are included in the data table. Limits for each analyte's detection by an instrument are reported in the table. The value -8888 indicates that the measurement for an analyte was below the detection limit and the value -7777 indicates that the measurement for an analyte was above the detection limit. Values of -9999 for concentration attributes indicate that no analysis was performed. Values of -9999 for detection limit attributes indicate that no information was available. Values of NaN for method attributes indicate that no information was available in columns containing text. Logical_Consistency_Report: No formal logical accuracy tests were conducted. Completeness_Report: Dataset is considered complete for the information presented, as described in the abstract. Many samples do not have chemistry data because analyses were performed on representative samples only. Users are advised to read the rest of the metadata record carefully for additional details. Positional_Accuracy: Horizontal_Positional_Accuracy: Horizontal_Positional_Accuracy_Report: A formal accuracy assessment of the horizontal positional information in the dataset has not been conducted. The horizontal accuracy was determined with the ship's GPS navigation, which is accurate to less than 5 m. Vertical_Positional_Accuracy: Vertical_Positional_Accuracy_Report: Depth information for samples was collected using ship sonar technology. A formal accuracy assessment of the vertical positional information in the dataset has not been conducted. Lineage: Source_Information: Source_Citation: Citation_Information: Originator: Activation Laboratories Ltd. (Actlabs), Ancaster, Ontario, Canada Publication_Date: 2023 Title: Geochemical Element Analysis Online_Linkage: https://actlabs.com/geochemistry/ Type_of_Source_Media: geochemical analyses Source_Time_Period_of_Content: Time_Period_Information: Range_of_Dates/Times: Beginning_Date: 20221118 Ending_Date: 20230727 Source_Currentness_Reference: Date range during which official lab reports were released by Activation Laboratories Ltd. (Actlabs). Source_Citation_Abbreviation: geochemistry Source_Contribution: Fe, Mn, Si, Al, Mg, Ca, Na, K, Ti, and P were determined by Lithium Borate Fusion / XRF (X-Ray Fluorescence); LOI (loss on ignition) was determined by Gravimetric analysis; H2OM (sorbed water) was determined by Gravimetric and IR; H2OP (structural water) was determined by Infrared; S and Cr were determined by Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids; Ag, Be, Bi Cd, Co, Ge, In, Mo, Pb, Re, Sc, Se, Sn, Sr, Te, Th, and Tl were determined by Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids; Au was determined by Instrumental Neutron Activation Analysis; Ba, Cs, Cu, Hf, Nb, Ni, Rb, Sb, Ta, U, V, W, Zn, Zr, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Y, Ho, Er, Tm, Yb, and Lu were determined by Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry; Hg was determined by Hg Cold Vapour FIMS (PerkinElmer Flow Injection Mercury System). As was determined by Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids and by Instrumental Neutron Activation Analysis; Li was determined by Inductively Coupled Plasma Optical Emission Spectroscopy, Inductively Coupled Plasma Mass Spectrometry, and four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids. Source_Information: Source_Citation: Citation_Information: Originator: Intertek, Maddington, Western Australia Publication_Date: 2024 Title: Platinum Group Element Analysis Online_Linkage: https://www.intertek.com/minerals/precious-metals-analysis/ Type_of_Source_Media: geochemical analyses Source_Time_Period_of_Content: Time_Period_Information: Single_Date/Time: Calendar_Date: 20240306 Source_Currentness_Reference: Date that official lab report was released by Intertek Source_Citation_Abbreviation: PGE data Source_Contribution: Platinum group element concentrations (PGE; Au, Ir, Os, Pd, Pt, Rh, Ru) were determined by fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Process_Step: Process_Description: Samples were collected via ROV from seamounts off the coast of Hawaii and within the Papahanaumokuakea Marine National Monument (PMNM) in the Pacific Ocean during E/V Nautilus expeditions NA134 and NA138 in 2021 and 2022, respectively. USGS scientists contributed to sample collection as remote participants from shore. Non-USGS collaborators were responsible for shipboard sample collection and initial sample handling. Subsamples were then sent to PCMSC and analyzed by USGS scientists to generate the data reported here. Process_Date: 20220501 Process_Step: Process_Description: Samples were sent to USGS for further subsampling and major and trace element geochemical analyses. Process_Date: 20230207 Process_Step: Process_Description: At USGS, bulk portions, individual layers, or other parts of sample were sampled using a ceramic knife and then ground using an agate mortar and pestle to approximately 75 micrometers. Powdered samples were then sent by USGS to commercial analytical labs, Activation Laboratories Ltd. (Actlabs) and Intertek. See Source Citations for information on geochemical techniques. Process_Date: 20230929 Process_Step: Process_Description: Four samples sent to Actlabs in duplicate: NA138-040-C-Bulk, NA138-054-1-Bulk, NA138-136-Bulk, and NA138-139-Bulk. Averaged concentrations of those duplicate samples are reported here. Duplicate Re concentrations for samples NA138-040-C-Bulk and NA138-054-1-Bulk included one value as below detection limit, so Re concentrations reported for these two samples is the value that was within the detection limit. Process_Date: 20230407 Process_Step: Process_Description: At USGS the water content (H2OM) of each sample was determined by gravimetric analysis (approximately 2 grams of material heated in a 105 degree Celsius oven for 2 hours and cooled in a desiccator prior to weighing). Weight percent water (H2OM values) calculated by USGS for all samples are reported here. Process_Date: 20240529 Process_Step: Process_Description: For samples from cruise ID NA134, USGS H2OM values were used to correct element concentrations in each sample to sorbed-water-free values using the following formula: water normalized = [raw element concentration]/[(100 - wt. percent water)/100]. For samples from cruise ID NA138, Actlabs H2OM values were used to correct element concentrations due to different sample handling. USGS values are still reported here as they more accurately represent total sorbed water. NA138-033-Bulk and NA138-091-B-Bulk did not have USGS H2OM values due to limited sample, for these samples an average of NA138 USGS H2O- values was used. NA138-033-Bulk has no reported Actlabs H20M value, averaged Actlabs H2OM values were used to generate normalized concentrations for NA138-033-Bulk. Process_Date: 20240808 Process_Step: Process_Description: Water normalized results from the lab analyses, detection limits, analytical method information, location data, and sample information were combined into a comma-delimited text values document (Hawaii_Seamounts_marine_minerals_geochemistry_data.csv). Source_Used_Citation_Abbreviation: geochemistry Process_Date: 20240809 Process_Step: Process_Description: This metadata file was edited to reflect that the overall data release was revised to include multiple datasets. No data were changed. (mau@usgs.gov) Process_Date: 20241211 Spatial_Data_Organization_Information: Direct_Spatial_Reference_Method: Point Point_and_Vector_Object_Information: SDTS_Terms_Description: SDTS_Point_and_Vector_Object_Type: Point Point_and_Vector_Object_Count: 53 Spatial_Reference_Information: Horizontal_Coordinate_System_Definition: Geographic: Latitude_Resolution: 0.0001 Longitude_Resolution: 0.0001 Geographic_Coordinate_Units: Decimal degrees Geodetic_Model: Horizontal_Datum_Name: D_WGS_1984 Ellipsoid_Name: WGS_1984 Semi-major_Axis: 6378137.0 Denominator_of_Flattening_Ratio: 298.257222101 Entity_and_Attribute_Information: Detailed_Description: Entity_Type: Entity_Type_Label: Hawaii_Seamounts_marine_mineral_geochemistry_data.csv Entity_Type_Definition: Comma-delimited file containing results from geochemical analyses of samples at the latitude, longitude, and water depth of each sample location. Entity_Type_Definition_Source: Producer defined Attribute: Attribute_Label: Cruise_ID Attribute_Definition: Lists the alphanumeric cruise identifier for the expedition during which the sample was collected Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NA134 Enumerated_Domain_Value_Definition: Cruise ID for 2021 NOAA E/V Nautilus expedition. Enumerated_Domain_Value_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NA138 Enumerated_Domain_Value_Definition: Cruise ID for 2022 NOAA E/V Nautilus expedition. Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Dive_ID Attribute_Definition: Lists the alphanumeric ROV dive identifier for the dive during which the sample was collected. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: ROV Hercules dive number beginning with "H". Attribute: Attribute_Label: Sample_ID Attribute_Definition: The cruise and sample ID for each sample Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Unique sample names include a cruise ID, a sample number, and may include further dashed numbers and/or letter(s) to denote the sample number. For NA138 samples, a number or letter after the sample number indicates a specific sample. For NA138 samples, "Bulk" and "Bulk-2" indicates analysis done without substrate, and "Bulk-1" indicates with substrate. Attribute: Attribute_Label: Latitude Attribute_Definition: Latitude at which sample was collected Attribute_Definition_Source: producer defined Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 22.1009 Range_Domain_Maximum: 33.0537 Attribute_Units_of_Measure: decimal degrees Attribute_Measurement_Resolution: 0.0001 Attribute: Attribute_Label: Longitude Attribute_Definition: Longitude at which sample was collected Attribute_Definition_Source: producer defined Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: -175.8771 Range_Domain_Maximum: -170.9241 Attribute_Units_of_Measure: decimal degrees Attribute_Measurement_Resolution: 0.0001 Attribute: Attribute_Label: Water_Depth_m Attribute_Definition: Water depth in meters at which the sample was collected. Depth information for samples was collected using ship sonar technology. Attribute_Definition_Source: producer defined Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 909 Range_Domain_Maximum: 3485 Attribute_Units_of_Measure: meters (m) Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Thickness_mm Attribute_Definition: The sample bulk or layer thickness, measured in millimeters from the top of the stratigraphic section, that encompasses each rock layer sample. Sample and layer subsample intervals are listed as ranges of integer values that represent the depth in millimeters below the surface. -8888 indicates that the sample is less than 1mm in thickness. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2 Range_Domain_Maximum: 45 Attribute_Units_of_Measure: millimeters (mm) Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Sample_Type Attribute_Definition: Description of sample material Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: bulk nodule Enumerated_Domain_Value_Definition: this is a bulk spherical nodule sample. Enumerated_Domain_Value_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: bulk crust Enumerated_Domain_Value_Definition: this is a bulk crust sample. Enumerated_Domain_Value_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: bulk coated cobble Enumerated_Domain_Value_Definition: this is a bulk sample of rounded cobble of rock that is broken from outcrop and changes position and orientation on the seafloor over time allowing ferromanganese crust to accrete on all or most of the surface of the substrate; crust layers may be non-uniform in thickness and/or sublayer orientation due to irregular growth, which differentiates coated cobbles from nodules. Enumerated_Domain_Value_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: crust layer Enumerated_Domain_Value_Definition: this is a layer of a crust sample. Enumerated_Domain_Value_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: nodule layer Enumerated_Domain_Value_Definition: this is a layer of a nodule sample. Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Fe_ppm Attribute_Definition: Iron concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 78900 Range_Domain_Maximum: 195300 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Mn_ppm Attribute_Definition: Manganese concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 78100 Range_Domain_Maximum: 301400 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Si_ppm Attribute_Definition: Silicon concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 7100 Range_Domain_Maximum: 135700 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Al_ppm Attribute_Definition: Aluminum concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1300 Range_Domain_Maximum: 43600 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Mg_ppm Attribute_Definition: Magnesium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 7600 Range_Domain_Maximum: 19400 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Ca_ppm Attribute_Definition: Calcium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 9800 Range_Domain_Maximum: 124400 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Na_ppm Attribute_Definition: Sodium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 3900 Range_Domain_Maximum: 19400 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: K_ppm Attribute_Definition: Potassium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 400 Range_Domain_Maximum: 12600 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Ti_ppm Attribute_Definition: Titanium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 4700 Range_Domain_Maximum: 15060 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: P_ppm Attribute_Definition: Phosphorus concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1800 Range_Domain_Maximum: 42700 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: S_ppm Attribute_Definition: Sulfur concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1200 Range_Domain_Maximum: 4 830 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: LOI_ppm Attribute_Definition: Loss on ignition when heated to 1000 C for each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 143700 Range_Domain_Maximum: 351700 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 100 Attribute: Attribute_Label: H2O M_ppm Attribute_Definition: Quantity of H2O-, or sorbed water, in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 64900 Range_Domain_Maximum: 259600 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 100 Attribute: Attribute_Label: H2OP_ppm Attribute_Definition: Quantity of H2O+, or structural water, in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 82000 Range_Domain_Maximum: 214000 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1000 Attribute: Attribute_Label: Ag_ppm Attribute_Definition: Silver concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.03 Range_Domain_Maximum: 0.74 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: As_ppm Attribute_Definition: Arsenic concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 114.7 Range_Domain_Maximum: 330.7 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Ba_ppm Attribute_Definition: Barium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 806 Range_Domain_Maximum: 4726 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Be_ppm Attribute_Definition: Beryllium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1.68 Range_Domain_Maximum: 6.51 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Bi_ppm Attribute_Definition: Bismuth concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 13.68 Range_Domain_Maximum: 130.25 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Cd_ppm Attribute_Definition: Cadmium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2.18 Range_Domain_Maximum: 10.61 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Co_ppm Attribute_Definition: Cobalt concentration in each sample. Values of -7777 indicate that the measurement was above the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1872.4 Range_Domain_Maximum: 10095.4 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Cr_ppm Attribute_Definition: Chromium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 8 Range_Domain_Maximum: 391 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Cs_ppm Attribute_Definition: Cesium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.1 Range_Domain_Maximum: 1.4 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Cu_ppm Attribute_Definition: Copper concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 286 Range_Domain_Maximum: 2429 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Ge_ppm Attribute_Definition: Germanium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit, and values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.16 Range_Domain_Maximum: 0.46 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Hf_ppm Attribute_Definition: Hafnium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1.6 Range_Domain_Maximum: 10.3 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Hg_ppm Attribute_Definition: Mercury concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.006 Range_Domain_Maximum: 0.008 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.001 Attribute: Attribute_Label: In_ppm Attribute_Definition: Indium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.110 Range_Domain_Maximum: 0.515 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.001 Attribute: Attribute_Label: Li_ppm Attribute_Definition: Lithium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1.0 Range_Domain_Maximum: 74.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Mo_ppm Attribute_Definition: Molybdenum concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 121.62 Range_Domain_Maximum: 1422.51 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Nb_ppm Attribute_Definition: Niobium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 31.8 Range_Domain_Maximum: 54.3 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Ni_ppm Attribute_Definition: Nickel concentration in each sample. Values of -7777 indicate that the measurement was above the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2630 Range_Domain_Maximum: 10174 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Pb_ppm Attribute_Definition: Lead concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 627.6 Range_Domain_Maximum: 2848.2 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Rb_ppm Attribute_Definition: Rubidium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 3 Range_Domain_Maximum: 32 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Re_ppm Attribute_Definition: Rubidium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.002 Range_Domain_Maximum: 0.026 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.001 Attribute: Attribute_Label: Sb_ppm Attribute_Definition: Antimony concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 29.4 Range_Domain_Maximum: 64.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Sc_ppm Attribute_Definition: Scandium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 3.5 Range_Domain_Maximum: 14.6 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Se_ppm Attribute_Definition: Selenium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit, and values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: -8888 Enumerated_Domain_Value_Definition: Values of -8888 indicate that the measurement was below the detection limit. Enumerated_Domain_Value_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: -9999 Enumerated_Domain_Value_Definition: Values of -9999 indicate that no analysis was performed. Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sn_ppm Attribute_Definition: Tin concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1.6 Range_Domain_Maximum: 11.5 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Sr_ppm Attribute_Definition: Strontium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 597.5 Range_Domain_Maximum: 2075.9 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Ta_ppm Attribute_Definition: Tantalum concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.12 Range_Domain_Maximum: 1.56 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Te_ppm Attribute_Definition: Tellurium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 14.30 Range_Domain_Maximum: 102.00 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Th_ppm Attribute_Definition: Thorium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 6.22 Range_Domain_Maximum: 57.53 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Tl_ppm Attribute_Definition: Thallium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 12.07 Range_Domain_Maximum: 231.23 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: U_ppm Attribute_Definition: Uranium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 4.72 Range_Domain_Maximum: 18.26 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: V_ppm Attribute_Definition: Vanadium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 293 Range_Domain_Maximum: 852 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: W_ppm Attribute_Definition: Tungsten concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 34.3 Range_Domain_Maximum: 170.0 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Zn_ppm Attribute_Definition: Zinc concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 434 Range_Domain_Maximum: 1008 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Zr_ppm Attribute_Definition: Zirconium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 21 Range_Domain_Maximum: 618 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: La_ppm Attribute_Definition: Lanthanum concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 111.57 Range_Domain_Maximum: 417.21 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Ce_ppm Attribute_Definition: Cerium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 339.51 Range_Domain_Maximum: 1904.76 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Pr_ppm Attribute_Definition: Praseodymium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 22.11 Range_Domain_Maximum: 92.90 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Nd_ppm Attribute_Definition: Neodyium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 93.12 Range_Domain_Maximum: 390.03 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Sm_ppm Attribute_Definition: Samarium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 18.87 Range_Domain_Maximum: 85.69 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Eu_ppm Attribute_Definition: Europium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 4.68 Range_Domain_Maximum: 20.33 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Gd_ppm Attribute_Definition: Gadolinium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 18.14 Range_Domain_Maximum: 81.91 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Tb_ppm Attribute_Definition: Terbium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2.64 Range_Domain_Maximum: 12.88 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Dy_ppm Attribute_Definition: Dysprosium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 15.30 Range_Domain_Maximum: 75.76 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.1 Attribute: Attribute_Label: Y_ppm Attribute_Definition: Yttrium content in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 55.60 Range_Domain_Maximum: 487.60 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Ho_ppm Attribute_Definition: Holmium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 2.91 Range_Domain_Maximum: 14.30 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Er_ppm Attribute_Definition: Erbium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 8.12 Range_Domain_Maximum: 40.06 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Tm_ppm Attribute_Definition: Thulium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1.126 Range_Domain_Maximum: 5.564 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.001 Attribute: Attribute_Label: Yb_ppm Attribute_Definition: Ytterbium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 7.42 Range_Domain_Maximum: 35.98 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.01 Attribute: Attribute_Label: Lu_ppm Attribute_Definition: Lutetium concentration in each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 1.210 Range_Domain_Maximum: 6.112 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.001 Attribute: Attribute_Label: SUM_REY Attribute_Definition: Summation of the concentration of rare earth elements (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) plus Y in each sample Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 896 Range_Domain_Maximum: 2921 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Percent_HREY Attribute_Definition: Percentage of the heavy rare earth elements calculated by taking the sum of heavy rare earth elements (Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) and Y and dividing by the SUM_REY for each sample. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 10 Range_Domain_Maximum: 39 Attribute_Units_of_Measure: percent Attribute_Measurement_Resolution: 1 Attribute: Attribute_Label: Au_ppm Attribute_Definition: Gold concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit, and values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.004 Range_Domain_Maximum: 0.027 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.001 Attribute: Attribute_Label: Ir Attribute_Definition: Iridium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.012 Range_Domain_Maximum: 0.034 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.001 Attribute: Attribute_Label: Os Attribute_Definition: Osmium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit, and values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: -8888 Enumerated_Domain_Value_Definition: Values of -8888 indicate that the measurement was below the detection limit. Enumerated_Domain_Value_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: -9999 Enumerated_Domain_Value_Definition: Values of -9999 indicate that no analysis was performed. Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Pd Attribute_Definition: Palladium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.006 Range_Domain_Maximum: 0.083 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.001 Attribute: Attribute_Label: Pt Attribute_Definition: Platinum concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.126 Range_Domain_Maximum: 0.561 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.001 Attribute: Attribute_Label: Rh Attribute_Definition: Rhenium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.008 Range_Domain_Maximum: 0.041 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.001 Attribute: Attribute_Label: Ru Attribute_Definition: Ruthenium concentration in each sample. Values of -9999 indicate that no analysis was performed. Attribute_Definition_Source: standard reporting value in geochemistry Attribute_Domain_Values: Range_Domain: Range_Domain_Minimum: 0.006 Range_Domain_Maximum: 0.033 Attribute_Units_of_Measure: parts per million Attribute_Measurement_Resolution: 0.001 Attribute: Attribute_Label: Fe_Detection_ppm Attribute_Definition: The lower detection limit for iron concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Mn_Detection_ppm Attribute_Definition: The lower detection limit for manganese concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Si_Detection_ppm Attribute_Definition: The lower detection limit for silicon concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Al_Detection_ppm Attribute_Definition: The lower detection limit for aluminum concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Mg_Detection_ppm Attribute_Definition: The lower detection limit for magnesium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ca_Detection_ppm Attribute_Definition: The lower detection limit for calcium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Na_Detection_ppm Attribute_Definition: The lower detection limit for sodium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: K_Detection_ppm Attribute_Definition: The lower detection limit for potassium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ti_Detection_ppm Attribute_Definition: The lower detection limit for titanium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: P_Detection_ppm Attribute_Definition: The lower detection limit for phosphorus concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: S_Detection_ppm Attribute_Definition: The lower detection limit for sulfur concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: LOI_Detection_ppm Attribute_Definition: The lower detection limit for loss on ignition based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: H2OM_Detection_ppm Attribute_Definition: The lower detection limit for H2OM, or sorbed water, concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: H2OP_Detection_ppm Attribute_Definition: The lower detection limit for H2OP, or structural water, concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ag_Detection_ppm Attribute_Definition: The lower detection limit for silver concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: As_Detection_ppm Attribute_Definition: The lower detection limit for arsenic concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ba_Detection_ppm Attribute_Definition: The lower detection limit for barium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Be_Detection_ppm Attribute_Definition: The lower detection limit for beryllium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Bi_Detection_ppm Attribute_Definition: The lower detection limit for bismuth concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Cd_Detection_ppm Attribute_Definition: The lower detection limit for cadmium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Co_Detection_ppm Attribute_Definition: The lower detection limit for cobalt concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Cr_Detection_ppm Attribute_Definition: The lower detection limit for chromium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Cs_Detection_ppm Attribute_Definition: The lower detection limit for cesium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Cu_Detection_ppm Attribute_Definition: The lower detection limit for copper concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ge_Detection_ppm Attribute_Definition: The lower detection limit for germanium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Hf_Detection_ppm Attribute_Definition: The lower detection limit for hafnium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Hg_Detection_ppm Attribute_Definition: The lower detection limit for mercury concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: In_Detection_ppm Attribute_Definition: The lower detection limit for indium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Li_Detection_ppm Attribute_Definition: The lower detection limit for lithium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Mo_Detection_ppm Attribute_Definition: The lower detection limit for molybdenum concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Nb_Detection_ppm Attribute_Definition: The lower detection limit for niobium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ni_Detection_ppm Attribute_Definition: The lower detection limit for nickel concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Pb_Detection_ppm Attribute_Definition: The lower detection limit for lead concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Rb_Detection_ppm Attribute_Definition: The lower detection limit for rubidium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Re_Detection_ppm Attribute_Definition: The lower detection limit for rhenium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sb_Detection_ppm Attribute_Definition: The lower detection limit for antimony concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sc_Detection_ppm Attribute_Definition: The lower detection limit for scandium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Se_Detection_ppm Attribute_Definition: The lower detection limit for selenium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sn_Detection_ppm Attribute_Definition: The lower detection limit for tin concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sr_Detection_ppm Attribute_Definition: The lower detection limit for strontium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ta_Detection_ppm Attribute_Definition: The lower detection limit for tantalum concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Te_Detection_ppm Attribute_Definition: The lower detection limit for tellurium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Th_Detection_ppm Attribute_Definition: The lower detection limit for thorium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Tl_Detection_ppm Attribute_Definition: The lower detection limit for thallium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: U_Detection_ppm Attribute_Definition: The lower detection limit for uranium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: V_Detection_ppm Attribute_Definition: The lower detection limit for vanadium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: W_Detection_ppm Attribute_Definition: The lower detection limit for tungsten concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Zn_Detection_ppm Attribute_Definition: The lower detection limit for zinc concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Zr_Detection_ppm Attribute_Definition: The lower detection limit for zirconium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: La_Detection_ppm Attribute_Definition: The lower detection limit for lanthanum concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ce_Detection_ppm Attribute_Definition: The lower detection limit for cerium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Pr_Detection_ppm Attribute_Definition: The lower detection limit for praseodymium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Nd_Detection_ppm Attribute_Definition: The lower detection limit for neodymium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Sm_Detection_ppm Attribute_Definition: The lower detection limit for samarium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Eu_Detection_ppm Attribute_Definition: The lower detection limit for europium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Gd_Detection_ppm Attribute_Definition: The lower detection limit for gadolinium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Tb_Detection_ppm Attribute_Definition: The lower detection limit for terbium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Dy_Detection_ppm Attribute_Definition: The lower detection limit for dysprosium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Y_Detection_ppm Attribute_Definition: The lower detection limit for yttrium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ho_Detection_ppm Attribute_Definition: The lower detection limit for holmium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Er_Detection_ppm Attribute_Definition: The lower detection limit for erbium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Tm_Detection_ppm Attribute_Definition: The lower detection limit for thulium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Yb_Detection_ppm Attribute_Definition: The lower detection limit for ytterbium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Lu_Detection_ppm Attribute_Definition: The lower detection limit for lutetium concentration based on the measurement method and instrumentation. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Au_Detection_ppm Attribute_Definition: The lower detection limit for gold concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ir_Detection Attribute_Definition: The lower detection limit for iridium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Os_Detection Attribute_Definition: The lower detection limit for osmium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Pd_Detection Attribute_Definition: The lower detection limit for palladium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Pt_Detection Attribute_Definition: The lower detection limit for platinum concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Rh_Detection Attribute_Definition: The lower detection limit for rhodium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Ru_Detection Attribute_Definition: The lower detection limit for ruthenium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million Attribute: Attribute_Label: Fe_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure iron concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-XRF Enumerated_Domain_Value_Definition: Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Mn_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure manganese concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-XRF Enumerated_Domain_Value_Definition: Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Si_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure silicon concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-XRF Enumerated_Domain_Value_Definition: Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Al_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure aluminum concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-XRF Enumerated_Domain_Value_Definition: Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Mg_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure magnesium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-XRF Enumerated_Domain_Value_Definition: Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ca_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure calcium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-XRF Enumerated_Domain_Value_Definition: Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Na_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure sodium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-XRF Enumerated_Domain_Value_Definition: Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: K_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure potassium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-XRF Enumerated_Domain_Value_Definition: Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ti_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure titanium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-XRF Enumerated_Domain_Value_Definition: Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: P_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure phosphorus concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-XRF Enumerated_Domain_Value_Definition: Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: S_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure sulfur concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-ICP Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: LOI_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure loss on ignition. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: GRAV Enumerated_Domain_Value_Definition: Gravimetric by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: H2OM_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure H2O-, or sorbed water, concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: GRAV-Moisture Enumerated_Domain_Value_Definition: Gravimetric and IR by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: H2OP_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure H2O+, or structural water, concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: H2O+ Enumerated_Domain_Value_Definition: Infrared by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ag_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure silver concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: As_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure aresenic concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ba_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure barium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Be_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure beryllium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Bi_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure bismuth concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Cd_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure cadmium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Co_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure cobalt concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Cr_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure chromium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-ICP Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Cs_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure cesium concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Cu_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure copper concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ge_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure germanium concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Hf_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure hafnium concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Hg_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure mercury concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: 1G Enumerated_Domain_Value_Definition: Hg Cold Vapour FIMS (PerkinElmer Flow Injection Mercury System) by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: In_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure indium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Li_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure lithium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-ICP Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Mo_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure molybdenum concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Nb_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure niobium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ni_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure nickel concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Pb_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure lead concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Rb_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure rubidium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Re_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure rubidium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sb_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure antimony concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sc_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure scandium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Se_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure selenium concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sn_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure tin concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sr_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure strontium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ta_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure tantalum concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Te_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure tellurium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Th_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure thorium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).v Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Tl_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure thallium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: TD-MS Enumerated_Domain_Value_Definition: Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: U_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure uranium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: V_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure vanadium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: W_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure tungsten concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Zn_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure zinc concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Zr_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure zirconium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: La_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure lanthanum concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ce_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure cerium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Pr_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure praseodymium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Nd_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure neodymium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Sm_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure samarium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Eu_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure europium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Gd_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure gadolinium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Tb_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure terbium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Dy_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure dysprosium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Y_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure yttrium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ho_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure holmium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).v Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Er_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure erbium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Tm_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure thulium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Yb_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure ytterbium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Lu_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure lutetium concentration. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: FUS-MS Enumerated_Domain_Value_Definition: Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Au_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure gold concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: INAA Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis by Activation Laboratories Ltd. (Actlabs). Enumerated_Domain_Value_Definition_Source: producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NS25H/MS Enumerated_Domain_Value_Definition: Fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) by Intertek analytical labs Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ir_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure iridium concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NS25H/MS Enumerated_Domain_Value_Definition: Fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) by Intertek analytical labs Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Os_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure osmium concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NS25H/MS Enumerated_Domain_Value_Definition: Fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) by Intertek analytical labs Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Pd_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure palladium concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NS25H/MS Enumerated_Domain_Value_Definition: Fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) by Intertek analytical labs Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Pt_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure platinum concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NS25H/MS Enumerated_Domain_Value_Definition: Fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) by Intertek analytical labs Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Rh_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure rhodium concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NS25H/MS Enumerated_Domain_Value_Definition: Fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) by Intertek analytical labs Enumerated_Domain_Value_Definition_Source: producer defined Attribute: Attribute_Label: Ru_Method Attribute_Definition: An alphanumeric code that denotes the method and instrumentation used to measure ruthenium concentration. NaN indicates that method information was not available. Attribute_Definition_Source: Producer defined Attribute_Domain_Values: Enumerated_Domain: Enumerated_Domain_Value: NS25H/MS Enumerated_Domain_Value_Definition: Fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) by Intertek analytical labs Enumerated_Domain_Value_Definition_Source: producer defined Overview_Description: Entity_and_Attribute_Overview: The first line of the csv file is a header line. Entity_and_Attribute_Detail_Citation: U.S. Geological Survey Distribution_Information: Distributor: Contact_Information: Contact_Organization_Primary: Contact_Organization: U.S. Geological Survey - ScienceBase Contact_Address: Address_Type: mailing and physical Address: Denver Federal Center, Building 810, Mail Stop 302 City: Denver State_or_Province: CO Postal_Code: 80225 Contact_Voice_Telephone: 1-888-275-8747 Contact_Electronic_Mail_Address: sciencebase@usgs.gov Resource_Description: These data are available in .csv format contained in a single file. Distribution_Liability: Unless otherwise stated, all data, metadata and related materials are considered to satisfy the quality standards relative to the purpose for which the data were collected. Although these data and associated metadata have been reviewed for accuracy and completeness and approved for release by the U.S. Geological Survey (USGS), no warranty expressed or implied is made regarding the display or utility of the data on any other system or for general or scientific purposes, nor shall the act of distribution constitute any such warranty. Standard_Order_Process: Digital_Form: Digital_Transfer_Information: Format_Name: comma-delimited text Format_Version_Number: Microsoft Excel 16.16.17 for Mac Format_Information_Content: File contains table in .csv format File_Decompression_Technique: No compression applied Transfer_Size: 0.06815 Digital_Transfer_Option: Online_Option: Computer_Contact_Information: Network_Address: Network_Resource_Name: https://www.sciencebase.gov/catalog/file/get/66bbe310d34e033882817489 Network_Resource_Name: https://www.sciencebase.gov/catalog/item/66bbe310d34e033882817489 Network_Resource_Name: https://doi.org/10.5066/P1WYF9T7 Access_Instructions: Data can be downloaded using the Network_Resource_Name links. The first link is a direct link to download a zipped file of data and metadata. The second link points to a landing page with metadata and data. The third link points to the landing page for the entire data release. Fees: None. Technical_Prerequisites: These data can be viewed with Microsoft Excel or any text reader. Metadata_Reference_Information: Metadata_Date: 20241219 Metadata_Contact: Contact_Information: Contact_Organization_Primary: Contact_Organization: U.S. Geological Survey, Pacific Coastal and Marine Science Center Contact_Person: PCMSC Science Data Coordinator Contact_Address: Address_Type: mailing and physical Address: 2885 Mission Street City: Santa Cruz State_or_Province: CA Postal_Code: 95060 Contact_Voice_Telephone: 831-427-4747 Contact_Electronic_Mail_Address: pcmsc_data@usgs.gov Metadata_Standard_Name: Content Standard for Digital Geospatial Metadata Metadata_Standard_Version: FGDC-STD-001-1998