Biomarker analysis of cold seeps along the United States Atlantic Margin

Metadata also available as - [Outline] - [Parseable text] - [XML]

Frequently anticipated questions:


What does this data set describe?

Title:
Biomarker analysis of cold seeps along the United States Atlantic Margin
Abstract:
Results of lipid biomarker concentration and compound specific isotopes analyzed from authigenic carbonates and surrounding sediment collected from Baltimore and Norfolk seep fields along the United States Atlantic Margin are presented in csv format. Samples were collected by the U.S. Geological Survey and Duke University between 2012 and 2015 using remotely operated vehicles (ROVs). Geochemical analysis was performed using gas chromatography (GC) and GC-combustion isotope ratio mass spectrometry (GC-C-IRMS).
Supplemental_Information:
Additional information about the USGS field activities from which some of these data were derived is available online at:
http://cmgds.marine.usgs.gov/fan_info.php?fan=F0112MC http://cmgds.marine.usgs.gov/fan_info.php?fan=B0413MC
Any use of trade, product, or firm names is for descriptive purposes only and does not imply endorsement by the U.S. Government.
  1. How might this data set be cited?
    Prouty, Nancy G., and Swarzenski, Pamela Campbell, 2019, Biomarker analysis of cold seeps along the United States Atlantic Margin: data release DOI:10.5066/P9JHGO8O, U.S. Geological Survey, Pacific Coastal and Marine Science Center, Santa Cruz, California.

    Online Links:

  2. What geographic area does the data set cover?
    West_Bounding_Coordinate: -74.4929
    East_Bounding_Coordinate: -73.7722
    North_Bounding_Coordinate: 38.0977
    South_Bounding_Coordinate: 36.8654
  3. What does it look like?
  4. Does the data set describe conditions during a particular time period?
    Beginning_Date: 25-Aug-2012
    Ending_Date: 21-Jul-2015
    Currentness_Reference:
    Ground condition at time data were collected.
  5. What is the general form of this data set?
    Geospatial_Data_Presentation_Form: comma-delimited text
  6. How does the data set represent geographic features?
    1. How are geographic features stored in the data set?
      This is a Point data set. It contains the following vector data types (SDTS terminology):
      • Point (28)
    2. What coordinate system is used to represent geographic features?
      Horizontal positions are specified in geographic coordinates, that is, latitude and longitude. Latitudes are given to the nearest 0.00001. Longitudes are given to the nearest 0.00001. Latitude and longitude values are specified in Decimal degrees. The horizontal datum used is D_WGS_1984.
      The ellipsoid used is WGS_1984.
      The semi-major axis of the ellipsoid used is 6378137.000000.
      The flattening of the ellipsoid used is 1/298.257224.
  7. How does the data set describe geographic features?
    USAM_MDAC_Biomarker.csv
    Table containing results from analyses of organic biomarker composition of authigenic carbonate and sediment samples. (Source: Producer defined)
    Sample ID
    The unique sample identification of a particular sample. (Source: producer defined) Sample IDs that begin with AT indicate samples collected by Duke University on the R/V Atlantis and include the ship’s cruise number (e.g. AT29-04), dive number (e.g. 4808), and sequential sample number. Sample IDs that begin with RB indicate samples collected by the USGS on the R/V Ron Brown and include the cruise year (e.g. 2013), dive number (e.g. 682), and sequential sample number. Sample IDs that begin with NF indicate samples collected by the USGS on the R/V Nancy Foster and include the cruise year (e.g. 2012), and a sequential number assigned by the vessel. Gaps in sequential numbers are common, as not all stations had samples collected or analyzed.
    Lab ID
    The unique laboratory identification of a particular sample. (Source: producer defined) The Lab ID contains the year of analysis in two digits (e.g., 18=2018) followed by a sample number in a series. Gaps in sequential numbers are common, and not all samples contain analytical description.
    Location
    Lists whether the sample was collected from either Baltimore Canyon or Norfolk Canyon. (Source: producer defined)
    ValueDefinition
    Baltimore CanyonName of canyon where sample was collected
    Norfolk CanyonName of canyon where sample was collected
    Date of Collection
    Calendar date (month/day/year) when sample was collected in the field (Source: producer defined)
    Range of values
    Minimum:8/25/12
    Maximum:7/21/15
    Units:month/day/year
    Depth
    Depth in meters of sample collection (Source: producer defined)
    Range of values
    Minimum:385
    Maximum:1617
    Units:meters (m)
    Resolution:1
    Latitude
    Latitude (Source: based on ship and ROV navigation systems)
    Range of values
    Minimum:36.8654
    Maximum:38.0977
    Units:decimal degrees
    Resolution:0.0001
    Longitude
    Longitude (Source: based on ship and ROV navigation systems)
    Range of values
    Minimum:-74.4929
    Maximum:-73.7722
    Units:decimal degrees
    Resolution:0.0001
    Sample type
    Explains the sample type (Source: producer defined)
    ValueDefinition
    mussel sedimentsediment collected from mussel habitat
    authigenic carbonatehomogenized authigenic carbonate rock
    bacterial mat sedimentsediment collected from bacterial mat habitat
    Depth interval
    Explains depth interval in sediment core for sample collection. n/a in the spreadsheet indicates not applicable. (Source: producer defined)
    ValueDefinition
    0-2sediment core depth interval at 0-2 cm
    2-5sediment core depth interval at 2-5 cm
    Percent Organic Carbon
    Sediment percent organic carbon as measured on an elemental analyzer. An empty cell in the spreadsheet indicates that percent carbon was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:0.29
    Maximum:5.14
    Units:molar percent (%)
    Resolution:0.01
    coprostanol
    Concentration of the sterol coprostanol normalized to dry weight. An empty cell in the spreadsheet indicates that coprostanol was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.04
    Maximum:0.97
    Units:microgram per gram dry weight
    Resolution:0.01
    epicoprostanol
    Concentration of the sterol epicoprostanol normalized to dry weight. An empty cell in the spreadsheet indicates that epicoprostanol was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:null
    Maximum:null
    Units:microgram per gram dry weight
    Resolution:0.01
    desmosterol
    Concentration of the sterol desmosterol normalized to dry weight. An empty cell in the spreadsheet indicates that desmosterol was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.09
    Maximum:0.25
    Units:microgram per gram dry weight
    Resolution:0.01
    5-B coprostanone
    Concentration of the sterol 5-B-coprostanone normalized to dry weight. An empty cell in the spreadsheet indicates that 5-B-coprostanone was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:null
    Maximum:null
    Units:microgram per gram dry weight
    Resolution:0.01
    cholesterol
    Concentration of the sterol cholesterol normalized to dry weight. An empty cell in the spreadsheet indicates that cholesterol was not calculated for that sample. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:2.05
    Maximum:15.30
    Units:microgram per gram dry weight
    Resolution:0.01
    cholestane
    Concentration of the sterol cholestane normalized to dry weight. An empty cell in the spreadsheet indicates that cholestane was not calculated for that sample. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.20
    Maximum:4.36
    Units:microgram per gram dry weight
    Resolution:0.01
    lanosterol
    Concentration of the sterol lanosterol normalized to dry weight. An empty cell in the spreadsheet indicates that lanosterol was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:null
    Maximum:null
    Units:microgram per gram dry weight
    Resolution:0.01
    cholestanol
    Concentration of the sterol cholestanol normalized to dry weight. An empty cell in the spreadsheet indicates that cholestanol was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:null
    Maximum:null
    Units:microgram per gram dry weight
    Resolution:0.01
    ergosterol
    Concentration of the sterol ergosterol normalized to dry weight. An empty cell in the spreadsheet indicates that ergosterol was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.12
    Maximum:6.72
    Units:microgram per gram dry weight
    Resolution:0.01
    4-methylcholest-diene
    Concentration of the sterol 4-methylcholest-diene normalized to dry weight. An empty cell in the spreadsheet indicates that 4-methylcholest-diene was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:null
    Maximum:null
    Units:microgram per gram dry weight
    Resolution:0.01
    campesterol
    Concentration of the sterol campesterol normalized to dry weight. An empty cell in the spreadsheet indicates that campesterol was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:2.70
    Maximum:2.70
    Units:microgram per gram dry weight
    Resolution:0.01
    stigmasterol
    Concentration of the sterol stigmasterol normalized to dry weight. An empty cell in the spreadsheet indicates that stigmasterol was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.06
    Maximum:0.53
    Units:microgram per gram dry weight
    Resolution:0.01
    B-sitosterol
    Concentration of the sterol B-sitosterol normalized to dry weight. An empty cell in the spreadsheet indicates that B-sitosterol was not calculated for that sample. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.22
    Maximum:4.50
    Units:microgram per gram dry weight
    Resolution:0.01
    stigmastanol
    Concentration of the sterol stigmastanol normalized to dry weight. An empty cell in the spreadsheet indicates that stigmastanol was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.47
    Maximum:1.46
    Units:microgram per gram dry weight
    Resolution:0.01
    archaeol
    Concentration of the sterol archaeol normalized to dry weight. An empty cell in the spreadsheet indicates that archaeol was not calculated for that sample. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.11
    Maximum:2.13
    Units:microgram per gram dry weight
    Resolution:0.01
    sn-2-hydroxyarchaeol
    Concentration of the sterol sn-2-hydroxyarchaeol normalized to dry weight. An empty cell in the spreadsheet indicates that sn-2-hydroxyarchaeol was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.01
    Maximum:0.32
    Units:microgram per gram dry weight
    Resolution:0.01
    crocetane
    Concentration of the alkane crocetane normalized to dry weight. An empty cell in the spreadsheet indicates that crocetane was not calculated for that sample. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.001
    Maximum:0.200
    Units:microgram per gram dry weight
    Resolution:0.001
    PMI
    concentration of the alkane pentamethylicosane (PMI) normalized to dry weight. An empty cell in the spreadsheet indicates that PMI was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.019
    Maximum:0.120
    Units:microgram per gram dry weight
    Resolution:0.001
    C14:0
    Concentration of the fatty acid C14:0 normalized to dry weight. An empty cell in the spreadsheet indicates that C14:0 was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.05
    Maximum:0.90
    Units:microgram per gram dry weight
    Resolution:0.01
    C14:1
    Concentration of the fatty acid C14:1 normalized to dry weight. An empty cell in the spreadsheet indicates that C14:1 was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.01
    Maximum:0.20
    Units:microgram per gram dry weight
    Resolution:0.01
    anteiso-C15:0
    Concentration of the fatty acid anteiso-C15:0 normalized to dry weight. An empty cell in the spreadsheet indicates that anteiso-C15:0 was not calculated for that sample. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.01
    Maximum:0.47
    Units:microgram per gram dry weight
    Resolution:0.01
    iso-C15:0
    Concentration of the fatty acid iso-C15:0 normalized to dry weight. An empty cell in the spreadsheet indicates that iso-C15:0 was not calculated for that sample. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.01
    Maximum:1.33
    Units:microgram per gram dry weight
    Resolution:0.01
    C15:0
    Concentration of the fatty acid C15:0 normalized to dry weight. An empty cell in the spreadsheet indicates that C15:0 was not calculated for that sample. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.01
    Maximum:0.27
    Units:microgram per gram dry weight
    Resolution:0.01
    C16:1 omega 5
    Concentration of the fatty acid C16:1 omega 5 normalized to dry weight. An empty cell in the spreadsheet indicates that C16:1 omega 5 was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.03
    Maximum:11.47
    Units:microgram per gram dry weight
    Resolution:0.01
    C16:1
    Concentration of the fatty acid C16:1 normalized to dry weight. An empty cell in the spreadsheet indicates that C16:1 was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.01
    Maximum:1.30
    Units:microgram per gram dry weight
    Resolution:0.01
    C16:0
    Concentration of the fatty acid C16:0 normalized to dry weight. An empty cell in the spreadsheet indicates that C16:0 was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.08
    Maximum:5.16
    Units:microgram per gram dry weight
    Resolution:0.01
    anteiso-C17:0
    Concentration of the fatty acid anteiso-C17:0 normalized to dry weight. An empty cell in the spreadsheet indicates that anteiso-C17:0 was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.01
    Maximum:0.37
    Units:microgram per gram dry weight
    Resolution:0.01
    C17:1
    Concentration of the fatty acid C17:1 normalized to dry weight. An empty cell in the spreadsheet indicates that C17:1 was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.01
    Maximum:0.18
    Units:microgram per gram dry weight
    Resolution:0.01
    C17:0
    Concentration of the fatty acid C17:0 normalized to dry weight. An empty cell in the spreadsheet indicates that C17:0 was not calculated for that sample. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.01
    Maximum:0.28
    Units:microgram per gram dry weight
    Resolution:0.01
    C18:1*
    Concentration of the fatty acid octadec-9-enoate/oleate (C18:1*) normalized to dry weight. An empty cell in the spreadsheet indicates that C18:1* was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.06
    Maximum:0.86
    Units:microgram per gram dry weight
    Resolution:0.01
    C18:1
    Concentration of the fatty acid octadec-11-enoate/oleate (C18:1) normalized to dry weight. An empty cell in the spreadsheet indicates that C18:1 was not calculated for that sample. BDL indicates concentration below detection limit. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.01
    Maximum:0.97
    Units:microgram per gram dry weight
    Resolution:0.01
    C18:0
    Concentration of the fatty acid C18:0 normalized to dry weight. An empty cell in the spreadsheet indicates that C18:0 was not calculated for that sample. BDL indicates concentration below detection limit. (Source: standard reporting value in organic chemistry)
    Range of values
    Minimum:0.01
    Maximum:7.58
    Units:microgram per gram dry weight
    Resolution:0.01
    cholesterol delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that cholesterol 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-66.75
    Maximum:-37.41
    Units:parts per thousand (per mil)
    Resolution:0.01
    cholestanol delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that cholestanol 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-77.97
    Maximum:-36.61
    Units:parts per thousand (per mil)
    Resolution:0.01
    B-sitosterol delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that B-sitosterol delta-C-13 was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-74.24
    Maximum:-35.26
    Units:parts per thousand (per mil)
    Resolution:0.01
    archaeol delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that archaeol 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-91.64
    Maximum:-58.36
    Units:parts per thousand (per mil)
    Resolution:0.01
    sn-2-hydroxyarchaeol delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that sn-2-hydroxyarchaeol 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-129.18
    Maximum:-80.33
    Units:parts per thousand (per mil)
    Resolution:0.01
    crocetane delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that crocetane 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-70.94
    Maximum:-26.39
    Units:parts per thousand (per mil)
    Resolution:0.01
    PMI delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that PMI 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-92.83
    Maximum:-29.87
    Units:parts per thousand (per mil)
    Resolution:0.01
    PMI (II) delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that PMI (II) 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-131.36
    Maximum:-120.62
    Units:parts per thousand (per mil)
    Resolution:0.01
    C14:0 delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that C14:0 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-53.02
    Maximum:-27.63
    Units:parts per thousand (per mil)
    Resolution:0.01
    C14:1 delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that C14:1 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-49.76
    Maximum:-26.27
    Units:parts per thousand (per mil)
    Resolution:0.01
    anteiso C15 delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that C14:1 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-107.56
    Maximum:-29.66
    Units:parts per thousand (per mil)
    Resolution:0.01
    iso C15 delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that iso-C15:0 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-105.87
    Maximum:-38.89
    Units:parts per thousand (per mil)
    Resolution:0.01
    C15:0 delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that C15:0 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-81.22
    Maximum:-26.11
    Units:parts per thousand (per mil)
    Resolution:0.01
    C16:0 compounda delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that unidentified branched and/or unsaturated C16:0 compound a 13C 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-126.00
    Maximum:-25.06
    Units:parts per thousand (per mil)
    Resolution:0.01
    C16:0 compound b delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that unidentified branched and/or unsaturated C16:0 compound b 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-123.65
    Maximum:-28.97
    Units:parts per thousand (per mil)
    Resolution:0.01
    C16:0 compound c delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that unidentified branched and/or unsaturated C16:0 compound c 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-126.06
    Maximum:-59.60
    Units:parts per thousand (per mil)
    Resolution:0.01
    C16:0 compound d delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that unidentified branched and/or unsaturated C16:0 compound d 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-126.97
    Maximum:-126.97
    Units:parts per thousand (per mil)
    Resolution:0.01
    C16:0 compound e delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that unidentified branched and/or unsaturated C16:0 compound e 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-110.49
    Maximum:-110.49
    Units:parts per thousand (per mil)
    Resolution:0.01
    C16:1 omega 5 delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that C16:1 omega 5 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-104.92
    Maximum:-36.78
    Units:parts per thousand (per mil)
    Resolution:0.01
    C16:1 delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that C16:1 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-95.44
    Maximum:-37.33
    Units:parts per thousand (per mil)
    Resolution:0.01
    C16:0 delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that C16:0 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-48.54
    Maximum:-25.54
    Units:parts per thousand (per mil)
    Resolution:0.01
    C18:0 delta-C-13
    delta-C-13 is a measure of the ratio of stable isotopes Carbon-13:Carbon-12, reported in parts per thousand (per mil). An empty cell in the spreadsheet indicates that C18:0 13C:12C was not calculated for that sample. (Source: standard reporting value in isotope chemistry)
    Range of values
    Minimum:-52.08
    Maximum:-28.51
    Units:parts per thousand (per mil)
    Resolution:0.01
    Entity_and_Attribute_Overview: The first line of the csv file is a header line.
    Entity_and_Attribute_Detail_Citation: U.S. Geological Survey

Who produced the data set?

  1. Who are the originators of the data set? (may include formal authors, digital compilers, and editors)
    • Nancy G. Prouty
    • Pamela Campbell Swarzenski
  2. Who also contributed to the data set?
    We wish to thank C. Van Dover (Duke University) for donating samples collected on board the R/V Atlantis, as well as A. Lam, B. Tipple, and M. Baker (USGS) and J. Herszage (UC Davis) for their analytical assistance.
  3. To whom should users address questions about the data?
    U.S. Geological Survey, Pacific Coastal and Marine Science Center
    Attn: PCMSC Science Data Coordinator
    2885 Mission Street
    Santa Cruz, CA

    831-427-4747 (voice)
    pcmsc_data@usgs.gov

Why was the data set created?

The purpose of making these measurements was to identify what microbial communities are driving anaerobic oxidation of methane at the Norfolk and Baltimore seep fields. The identification and distribution of these microbial communities represents a key component to understanding the global methane cycle including both short- and long-term methane storage.

How was the data set created?

  1. From what previous works were the data drawn?
  2. How were the data generated, processed, and modified?
    Date: 15-Dec-2018 (process 1 of 2)
    Carbonate and sediment samples from pushcores were collected from ROV operations. Samples were stored frozen. The biomarker composition of the authigenic carbonate and sediment samples was determined by gas chromatography-mass spectrometry (GC-MS) at the USGS Organic Geochemistry laboratory in Santa Cruz, California. The samples were subsequently extracted using the Dionex ASE with a mixture of dichloromethane and methanol (9:1; v:v). Prior to extraction, internal standards were added (5-α androstane, 5α- 3β androstanol, ortho-terphenyl, and nonadecanoic acid). The total lipid extracts were passed though funnels containing sodium sulfate to remove excess water followed by saponification with 6% KOH (w/v) in methanol at 70°C for 3 hours. After cooling, the neutral fractions were extracted 3–5 times with hexane until the extracts turned colorless. To obtain fatty acids, the residuals were treated with 10% HCl to pH ~ 2 and extracted 3 times with hexane. The neutral fractions were separated by column chromatography into compound classes: (1) hydrocarbons (n-hexane), (2) aromatics (toluene:hexane) and (3) alcohols (ethyl acetate:hexane, methanol). The alcohols were converted to trimethylsiloxyl derivatives by bis (trimethylsilyl) trifluoroacetamide (BSTFA with 1% TMCS) heated at 60 °C for 1 h prior to GC–MS analysis. Fatty acids were converted to methyl esters by drying and subjecting the fraction to 14% BF3-methanol in a screw cap vial at 60 °C for 2 h. Compound specific isotope analysis (CSIA) on select biomarkers in the carbonate and sediment samples was determined by GC-combustion isotope ratio mass spectrometry (GC-C-IRMS). Carbon isotopic compositions of sterols and n-alkanes were measured at the Stable Isotope Facility at University of California, Davis using a Thermo GC-C-IRMS system composed of a Trace GC Ultra gas chromatograph coupled to a Delta V Advantage IRMS through a GC-C-III interface with compound identification support for the CSIA laboratory provided by a Varian CP3800 gas chromatograph coupled to a Saturn 2200 ion trap MS/MS. CSIA composition of the fatty acids was performed at the Marine Organic and Isotope Geochemistry lab at the University of Miami by GC-C-IRMS. Samples were dissolved in hexane and injected manually in splitless mode into a Thermo GC-C-IRMS system (Trace GC 1310 coupled to an Isolink II combustion interface, Conflo IV interface, and MAT 253 isotope ratio mass spectrometer). Results from the all lab analyses were combined into a comma-delimited text document (USAM_MDAC_Biomarker.csv) for this data release.
    Date: 19-Oct-2020 (process 2 of 2)
    Edited metadata to add keywords section with USGS persistent identifier as theme keyword. No data were changed. Person who carried out this activity:
    U.S. Geological Survey
    Attn: VeeAnn A. Cross
    Marine Geologist
    384 Woods Hole Road
    Woods Hole, MA

    508-548-8700 x2251 (voice)
    508-457-2310 (FAX)
    vatnipp@usgs.gov
  3. What similar or related data should the user be aware of?
    Prouty, Nancy G., Sahy, Diana, Ruppel, Carolyn D., Roark, E. Brendan, Condon, Dan, Brook, Sandra, Ross, Steve W., and Demopoulos, Amanda W.J., 2016, Earth and Planetary Science Letters.

    Online Links:

    Other_Citation_Details:
    Prouty, N.G., Sahy, D., Ruppel, C.D., Roark, E.B., Condon, D., Brooke S., Ross, S.W., and Demopoulos, A.W.J., 2016, Insights into methane dynamics from analysis of authigenic carbonates and chemosynthetic mussels at newly-discovered Atlantic Margin seeps: Earth and Planetary Science Letters, v. 449, p., 332-344.

How reliable are the data; what problems remain in the data set?

  1. How well have the observations been checked?
    All geochemistry data were calibrated against known standards.
  2. How accurate are the geographic locations?
    A formal accuracy assessment of the horizontal positional information in the data set has not been conducted.
  3. How accurate are the heights or depths?
    A formal accuracy assessment of the vertical positional information in the data set has not been conducted.
  4. Where are the gaps in the data? What is missing?
    Dataset is considered complete for the information presented, as described in the abstract. Gaps in sequential sample ID numbers are common, as not all stations had samples collected or analyzed. An empty cell in the spreadsheet indicates that lanosterol was not calculated for that sample. BDL indicates concentration below detection limit. Users are advised to read the rest of the metadata record carefully for additional details.
  5. How consistent are the relationships among the observations, including topology?
    No formal logical accuracy tests were conducted.

How can someone get a copy of the data set?

Are there legal restrictions on access or use of the data?
Access_Constraints: None
Use_Constraints:
USGS-authored or produced data and information are in the public domain from the U.S. Government and are freely redistributable with proper metadata and source attribution. Please recognize and acknowledge the U.S. Geological Survey and Atmospheric Administration (NOAA), and Bureau of Ocean Energy Management (BOEM) as the originator(s) of the dataset and in products derived from these data.
  1. Who distributes the data set? (Distributor 1 of 1)
    U.S. Geological Survey - ScienceBase
    Denver Federal Center, Building 810, Mail Stop 302
    Denver, CO

    1-888-275-8747 (voice)
    sciencebase@usgs.gov
  2. What's the catalog number I need to order this data set? These data are available in .csv format contained in a single file.
  3. What legal disclaimers am I supposed to read?
    Unless otherwise stated, all data, metadata and related materials are considered to satisfy the quality standards relative to the purpose for which the data were collected. Although these data and associated metadata have been reviewed for accuracy and completeness and approved for release by the U.S. Geological Survey (USGS), no warranty expressed or implied is made regarding the display or utility of the data on any other system or for general or scientific purposes, nor shall the act of distribution constitute any such warranty.
  4. How can I download or order the data?
  5. What hardware or software do I need in order to use the data set?
    These data can be viewed with Microsoft Excel or any text reader

Who wrote the metadata?

Dates:
Last modified: 19-Oct-2020
Metadata author:
U.S. Geological Survey, Pacific Coastal and Marine Science Center
Attn: PCMSC Science Data Coordinator
2885 Mission Street
Santa Cruz, CA

831-427-4747 (voice)
pcmsc_data@usgs.gov
Metadata standard:
Content Standard for Digital Geospatial Metadata (FGDC-STD-001-1998)

This page is <https://cmgds.marine.usgs.gov/catalog/pcmsc/DataReleases/ScienceBase/DR_P9JHGO8O/USAM_MDAC_Biomarker_metadata.faq.html>
Generated by mp version 2.9.50 on Tue Sep 21 18:17:23 2021