Entity_Type:
Entity_Type_Label: VonDamm_geochemistry_rawdata.csv
Entity_Type_Definition:
Comma-delimited file containing results from major, minor and trace element analyses of rock samples.
Entity_Type_Definition_Source: Producer defined
Attribute:
Attribute_Label: Cruise_ID
Attribute_Definition:
Lists the alphanumeric cruise identifier for the expedition during which the sample was collected
Attribute_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: AT42-22
Enumerated_Domain_Value_Definition:
IMR cruise identification affiliated with Field Activity 2020-602-FA
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sample_ID
Attribute_Definition: The sample ID for each sample
Attribute_Definition_Source: producer defined
Attribute_Domain_Values:
Unrepresentable_Domain:
The sample names include a dive number (ROV, denoting remotely operated vehicle, followed by a number) and rock number (R, denoting rock, followed by a number).
Attribute:
Attribute_Label: Latitude
Attribute_Definition: Latitude at which sample was collected
Attribute_Definition_Source: producer defined
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 18.3747419
Range_Domain_Maximum: 18.3763850
Attribute_Units_of_Measure: decimal degrees
Attribute_Measurement_Resolution: 0.0000001
Attribute:
Attribute_Label: Longitude
Attribute_Definition: Longitude at which sample was collected
Attribute_Definition_Source: producer defined
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -81.7980902
Range_Domain_Maximum: -81.7971780
Attribute_Units_of_Measure: decimal degrees
Attribute_Measurement_Resolution: 0.0000001
Attribute:
Attribute_Label: Water_Depth
Attribute_Definition: Water depth in meters at which the sample was collected.
Attribute_Definition_Source: producer defined
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2360
Range_Domain_Maximum: 2388
Attribute_Units_of_Measure: meters (m)
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Sublocation name
Attribute_Definition:
Specific location within the vent field where sample was collected
Attribute_Definition_Source: producer defined
Attribute_Domain_Values:
Unrepresentable_Domain:
Locations within the vent field were previously named in McDermott, J. M., Seewald, J. S., German, C. R., & Sylva, S. P. (2015). Pathways for abiotic organic synthesis at submarine hydrothermal fields.�Proceedings of the National Academy of Sciences,�112(25), 7668-7672.
Attribute:
Attribute_Label: Fe
Attribute_Definition: Iron concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1888
Range_Domain_Maximum: 11749
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Mn
Attribute_Definition: Manganese concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 107
Range_Domain_Maximum: 1346
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Si
Attribute_Definition: Silicon concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 138520
Range_Domain_Maximum: 304716
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Al
Attribute_Definition: Aluminum concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 158
Range_Domain_Maximum: 3545
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Mg
Attribute_Definition: Magnesium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 139151
Range_Domain_Maximum: 172024
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Ca
Attribute_Definition: Calcium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 429
Range_Domain_Maximum: 98128
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Na
Attribute_Definition: Sodium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2003
Range_Domain_Maximum: 7122
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: K
Attribute_Definition: Potassium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 332
Range_Domain_Maximum: 1079
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Ti
Attribute_Definition:
Titanium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: P
Attribute_Definition:
Phosphorus concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 43
Range_Domain_Maximum: 436
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: S
Attribute_Definition: Sulfur concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 170
Range_Domain_Maximum: 6440
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 10
Attribute:
Attribute_Label: Ag
Attribute_Definition: Silver concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.05
Range_Domain_Maximum: 76.93
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: As
Attribute_Definition: Arsenic concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2
Range_Domain_Maximum: 25
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: B
Attribute_Definition:
Boron concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Ba
Attribute_Definition: Barium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1
Range_Domain_Maximum: 13
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Be
Attribute_Definition:
Berrylium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.1
Range_Domain_Maximum: 0.3
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Bi
Attribute_Definition:
Bismuth concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Br
Attribute_Definition:
Bromine concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Cd
Attribute_Definition: Cadmium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.04
Range_Domain_Maximum: 2.36
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Cl
Attribute_Definition:
Chlorine concentration in each sample. Values of -7777 indicate that the value was above the technique limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1962
Range_Domain_Maximum: 4782
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Co
Attribute_Definition: Cobalt concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.2
Range_Domain_Maximum: 21.9
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Cr
Attribute_Definition: Chromium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2
Range_Domain_Maximum: 11
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Cs
Attribute_Definition:
Cesium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.1
Range_Domain_Maximum: 0.2
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Cu
Attribute_Definition: Copper concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 95.2
Range_Domain_Maximum: 6436.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: F
Attribute_Definition: Fluorine concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1172
Range_Domain_Maximum: 3346
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Ga
Attribute_Definition: Gallium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 3.9
Range_Domain_Maximum: 38.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Ge
Attribute_Definition:
Germanium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1
Range_Domain_Maximum: 3
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Hf
Attribute_Definition:
Hafnium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Hg
Attribute_Definition:
Mercury concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.135
Range_Domain_Maximum: 1.232
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.001
Attribute:
Attribute_Label: In
Attribute_Definition:
Indium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Li
Attribute_Definition: Lithium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 22
Range_Domain_Maximum: 134
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Mo
Attribute_Definition: Molybdenum concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.24
Range_Domain_Maximum: 10.05
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Nb
Attribute_Definition:
Niobium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Ni
Attribute_Definition: Nickel concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2
Range_Domain_Maximum: 25
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Pb
Attribute_Definition: Lead concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.6
Range_Domain_Maximum: 117.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Rb
Attribute_Definition: Rubidium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.4
Range_Domain_Maximum: 3.5
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Sb
Attribute_Definition: Antimony concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.15
Range_Domain_Maximum: 26.90
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Sc
Attribute_Definition:
Scandium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Se
Attribute_Definition:
Selenium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Sn
Attribute_Definition:
Tin concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Sr
Attribute_Definition: Strontium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 6.8
Range_Domain_Maximum: 208.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Ta
Attribute_Definition:
Tantalum concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Te
Attribute_Definition: Tellurium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.11
Range_Domain_Maximum: 6.87
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Th
Attribute_Definition:
Thorium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Tl
Attribute_Definition: Thallium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.04
Range_Domain_Maximum: 21.69
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: U
Attribute_Definition: Uranium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 7.33
Range_Domain_Maximum: 62.99
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: V
Attribute_Definition: Vanadium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 13
Range_Domain_Maximum: 50
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: W
Attribute_Definition:
Tungsten concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.2
Range_Domain_Maximum: 1.6
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Zn
Attribute_Definition: Zinc concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 12
Range_Domain_Maximum: 443
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Zr
Attribute_Definition: Zirconium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.6
Range_Domain_Maximum: 8.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: La
Attribute_Definition: Lanthanum concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.1
Range_Domain_Maximum: 1.9
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Ce
Attribute_Definition: Cerium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.2
Range_Domain_Maximum: 8.7
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Pr
Attribute_Definition:
Praseodymium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.07
Range_Domain_Maximum: 0.49
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Nd
Attribute_Definition: Neodyium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.1
Range_Domain_Maximum: 1.9
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Sm
Attribute_Definition: Samarium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.2
Range_Domain_Maximum: 0.6
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Eu
Attribute_Definition:
Europium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.15
Range_Domain_Maximum: 2.29
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Gd
Attribute_Definition: Gadolinium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.07
Range_Domain_Maximum: 0.51
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Tb
Attribute_Definition:
Terbium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Dy
Attribute_Definition:
Dysprosium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.07
Range_Domain_Maximum: 0.40
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Y
Attribute_Definition: Yttrium content in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.2
Range_Domain_Maximum: 2.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Ho
Attribute_Definition:
Holmium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Er
Attribute_Definition:
Erbium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.05
Range_Domain_Maximum: 0.25
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Tm
Attribute_Definition:
Thulium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Yb
Attribute_Definition:
Ytterbium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -9999
Range_Domain_Maximum: -9999
Attribute_Units_of_Measure: parts per million
Attribute:
Attribute_Label: Lu
Attribute_Definition:
Lutetium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.01
Range_Domain_Maximum: 0.04
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Au
Attribute_Definition:
Gold concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.0017
Range_Domain_Maximum: 0.6855
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.0001
Attribute:
Attribute_Label: TOC
Attribute_Definition: Total organic carbon concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 769
Range_Domain_Maximum: 15950
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: TIC
Attribute_Definition: Total inorganic carbon concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 11
Range_Domain_Maximum: 53748
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Fe_Detection
Attribute_Definition:
The detection limit for iron concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Mn_Detection
Attribute_Definition:
The detection limit for manganese concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Si_Detection
Attribute_Definition:
The detection limit for silicon concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Al_Detection
Attribute_Definition:
The detection limit for aluminum concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Mg_Detection
Attribute_Definition:
The detection limit for magnesium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ca_Detection
Attribute_Definition:
The detection limit for calcium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Na_Detection
Attribute_Definition:
The detection limit for sodium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: K_Detection
Attribute_Definition:
The detection limit for potassium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ti_Detection
Attribute_Definition:
The detection limit for titanium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: P_Detection
Attribute_Definition:
The detection limit for phosphorus concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: S_Detection
Attribute_Definition:
The detection limit for sulfur concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ag_Detection
Attribute_Definition:
The detection limit for silver concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: As_Detection
Attribute_Definition:
The detection limit for arsenic concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: B_Detection
Attribute_Definition:
The detection limit for boron concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ba_Detection
Attribute_Definition:
The detection limit for barium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Be_Detection
Attribute_Definition:
The detection limit for beryllium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Bi_Detection
Attribute_Definition:
The detection limit for bismuth concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Br_Detection
Attribute_Definition:
The detection limit for bromine concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Cd_Detection
Attribute_Definition:
The detection limit for cadmium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Cl_Detection
Attribute_Definition:
The detection limit for chlorine concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Co_Detection
Attribute_Definition:
The detection limit for cobalt concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Cr_Detection
Attribute_Definition:
The detection limit for chromium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Cs_Detection
Attribute_Definition:
The detection limit for cesium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Cu_Detection
Attribute_Definition:
The detection limit for copper concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: F_Detection
Attribute_Definition:
The detection limit for fluorine concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ga_Detection
Attribute_Definition:
The detection limit for gallium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ge_Detection
Attribute_Definition:
The detection limit for germanium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Hf_Detection
Attribute_Definition:
The detection limit for hafnium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Hg_Detection
Attribute_Definition:
The detection limit for mercury concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: In_Detection
Attribute_Definition:
The detection limit for indium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Li_Detection
Attribute_Definition:
The detection limit for lithium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Mo_Detection
Attribute_Definition:
The detection limit for molybdenum concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Nb_Detection
Attribute_Definition:
The detection limit for niobium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ni_Detection
Attribute_Definition:
The detection limit for nickel concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Pb_Detection
Attribute_Definition:
The detection limit for lead concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Rb_Detection
Attribute_Definition:
The detection limit for rubidium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sb_Detection
Attribute_Definition:
The detection limit for antimony concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sc_Detection
Attribute_Definition:
The detection limit for scandium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Se_Detection
Attribute_Definition:
The detection limit for selenium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sn_Detection
Attribute_Definition:
The detection limit for tin concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sr_Detection
Attribute_Definition:
The detection limit for strontium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ta_Detection
Attribute_Definition:
The detection limit for tantalum concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Te_Detection
Attribute_Definition:
The detection limit for tellurium concentration based on the measurement method and instrumentation. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Th_Detection
Attribute_Definition:
The detection limit for thorium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Tl_Detection
Attribute_Definition:
The detection limit for thallium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: U_Detection
Attribute_Definition:
The detection limit for uranium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: V_Detection
Attribute_Definition:
The detection limit for vanadium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: W_Detection
Attribute_Definition:
The detection limit for tungsten concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Zn_Detection
Attribute_Definition:
The detection limit for zinc concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Zr_Detection
Attribute_Definition:
The detection limit for zirconium concentration based on the measurement method and instrumentation. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: La_Detection
Attribute_Definition:
The detection limit for lanthanum concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ce_Detection
Attribute_Definition:
The detection limit for cerium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Pr_Detection
Attribute_Definition:
The detection limit for praseodymium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Nd_Detection
Attribute_Definition:
The detection limit for neodymium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sm_Detection
Attribute_Definition:
The detection limit for samarium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Eu_Detection
Attribute_Definition:
The detection limit for europium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Gd_Detection
Attribute_Definition:
The detection limit for gadolinium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Tb_Detection
Attribute_Definition:
The detection limit for terbium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Dy_Detection
Attribute_Definition:
The detection limit for dysprosium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Y_Detection
Attribute_Definition:
The detection limit for yttrium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ho_Detection
Attribute_Definition:
The detection limit for holmium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Er_Detection
Attribute_Definition:
The detection limit for erbium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Tm_Detection
Attribute_Definition:
The detection limit for thulium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Yb_Detection
Attribute_Definition:
The detection limit for ytterbium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Lu_Detection
Attribute_Definition:
The detection limit for lutetium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Au_Detection
Attribute_Definition:
The detection limit for gold concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: TOC_Detection
Attribute_Definition:
The detection limit for total organic carbon concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: TIC_Detection
Attribute_Definition:
The detection limit for total inorganic carbon concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Fe_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure iron concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: XRF_BF2
Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Mn_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure manganese concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Si_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure silicon concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: XRF_BF2
Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Al_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure aluminum concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: XRF_BF2
Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Mg_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure magnesium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: XRF_BF2
Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ca_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure calcium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: XRF_BF2
Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Na_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure sodium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: XRF_BF2
Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: K_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure potassium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: XRF_BF2
Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ti_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure titanium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NaN
Enumerated_Domain_Value_Definition: method information not available
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: P_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure phosphorus concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: XRF_BF2
Enumerated_Domain_Value_Definition: X-Ray fluorescence (XRF) on borate fused disks
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: S_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure sulfur concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: IR
Enumerated_Domain_Value_Definition: IR Combustion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ag_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure silver concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP-OES_4ACID
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: As_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure arsenic concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_AR
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: B_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure boron concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NaN
Enumerated_Domain_Value_Definition: Method information not available
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ba_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure barium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP-OES_4ACID
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Be_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure beryllium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_AR
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Bi_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure bismuth concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NaN
Enumerated_Domain_Value_Definition: Method information was not available
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Br_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure bromine concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NaN
Enumerated_Domain_Value_Definition: Method information was not available
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Cd_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure cadmium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_AR
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Cl_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure chlorine concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ISE
Enumerated_Domain_Value_Definition: Ion Selective Electrode
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Co_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure cobalt concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_AR
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Cr_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure chromium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP-OES_4ACID
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Cs_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure cesium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Cu_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure copper concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP-OES_4ACID
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: F_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure flourine concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ISE
Enumerated_Domain_Value_Definition: Ion Selective Electrode
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ga_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure gallium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_AR
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ge_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure germanium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Hf_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure hafnium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NaN
Enumerated_Domain_Value_Definition: Method information not available
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Hg_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure mercury concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: CVAAS
Enumerated_Domain_Value_Definition: Cold Vapor Atomic Absorption Spectroscopy
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: In_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure indium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NaN
Enumerated_Domain_Value_Definition: Method information not available
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Li_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure lithium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP-OES_4ACID
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Mo_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure molybdenum concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_AR
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Nb_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure niobium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NaN
Enumerated_Domain_Value_Definition: Method information not available
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ni_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure nickel concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP-OES_4ACID
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Pb_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure lead concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_AR
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Rb_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure rubidium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_AR
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sb_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure antimony concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_AR
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sc_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure scandium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NaN
Enumerated_Domain_Value_Definition: Method information not available
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Se_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure selenium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NaN
Enumerated_Domain_Value_Definition: Method information not available
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sn_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure tin concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NaN
Enumerated_Domain_Value_Definition: Method information not available
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sr_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure strontium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP-OES_4ACID
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ta_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure tantalum concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NaN
Enumerated_Domain_Value_Definition: Method information not available
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Te_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure tellurium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_AR
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Th_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure thorium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NaN
Enumerated_Domain_Value_Definition: Method information not available
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Tl_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure thallium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_AR
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: U_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure uranium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_AR
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: V_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure vanadium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP-OES_4ACID
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: W_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure tungsten concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_AR
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, aqua regia digestion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Zn_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure zinc concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP-OES_4ACID
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, hydrofluoric, nitric, perchloric acids
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Zr_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure zirconium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_HNO3_LiMB
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, lithium metaborate fusion followed by nitric acid digestion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: La_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure lanthanum concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ce_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure cerium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Pr_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure praseodymium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Nd_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure neodymium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sm_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure samarium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Eu_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure europium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Gd_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure gadolinium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Tb_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure terbium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Dy_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure dysprosium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Y_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure yttrium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ho_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure holmium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Er_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure erbium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Tm_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure thulium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Yb_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure ytterbium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Lu_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure lutetium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Au_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure gold concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_NiS_FA
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, nickel sulfide fire assay
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: TOC_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure total organic carbon concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: Wt_difference
Enumerated_Domain_Value_Definition: Sample weight difference
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: TIC_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure total inorganic carbon concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: UIC
Enumerated_Domain_Value_Definition: UIC CM5230 acid digester attached to a CM5017 coulometer
Enumerated_Domain_Value_Definition_Source: producer defined