Entity_Type:
Entity_Type_Label: Hawaii_Seamounts_marine_mineral_geochemistry_data.csv
Entity_Type_Definition:
Comma-delimited file containing results from geochemical analyses of samples at the latitude, longitude, and water depth of each sample location.
Entity_Type_Definition_Source: Producer defined
Attribute:
Attribute_Label: Cruise_ID
Attribute_Definition:
Lists the alphanumeric cruise identifier for the expedition during which the sample was collected
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NA134
Enumerated_Domain_Value_Definition: Cruise ID for 2021 NOAA E/V Nautilus expedition.
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NA138
Enumerated_Domain_Value_Definition: Cruise ID for 2022 NOAA E/V Nautilus expedition.
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Dive_ID
Attribute_Definition:
Lists the alphanumeric ROV dive identifier for the dive during which the sample was collected.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: ROV Hercules dive number beginning with "H".
Attribute:
Attribute_Label: Sample_ID
Attribute_Definition: The cruise and sample ID for each sample
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain:
Unique sample names include a cruise ID, a sample number, and may include further dashed numbers and/or letter(s) to denote the sample number. For NA138 samples, a number or letter after the sample number indicates a specific sample. For NA138 samples, "Bulk" and "Bulk-2" indicates analysis done without substrate, and "Bulk-1" indicates with substrate.
Attribute:
Attribute_Label: Latitude
Attribute_Definition: Latitude at which sample was collected
Attribute_Definition_Source: producer defined
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 22.1009
Range_Domain_Maximum: 33.0537
Attribute_Units_of_Measure: decimal degrees
Attribute_Measurement_Resolution: 0.0001
Attribute:
Attribute_Label: Longitude
Attribute_Definition: Longitude at which sample was collected
Attribute_Definition_Source: producer defined
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -175.8771
Range_Domain_Maximum: -170.9241
Attribute_Units_of_Measure: decimal degrees
Attribute_Measurement_Resolution: 0.0001
Attribute:
Attribute_Label: Water_Depth_m
Attribute_Definition:
Water depth in meters at which the sample was collected. Depth information for samples was collected using ship sonar technology.
Attribute_Definition_Source: producer defined
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 909
Range_Domain_Maximum: 3485
Attribute_Units_of_Measure: meters (m)
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Thickness_mm
Attribute_Definition:
The sample bulk or layer thickness, measured in millimeters from the top of the stratigraphic section, that encompasses each rock layer sample. Sample and layer subsample intervals are listed as ranges of integer values that represent the depth in millimeters below the surface. -8888 indicates that the sample is less than 1mm in thickness.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2
Range_Domain_Maximum: 45
Attribute_Units_of_Measure: millimeters (mm)
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Sample_Type
Attribute_Definition: Description of sample material
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: bulk nodule
Enumerated_Domain_Value_Definition: this is a bulk spherical nodule sample.
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: bulk crust
Enumerated_Domain_Value_Definition: this is a bulk crust sample.
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: bulk coated cobble
Enumerated_Domain_Value_Definition:
this is a bulk sample of rounded cobble of rock that is broken from outcrop and changes position and orientation on the seafloor over time allowing ferromanganese crust to accrete on all or most of the surface of the substrate; crust layers may be non-uniform in thickness and/or sublayer orientation due to irregular growth, which differentiates coated cobbles from nodules.
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: crust layer
Enumerated_Domain_Value_Definition: this is a layer of a crust sample.
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: nodule layer
Enumerated_Domain_Value_Definition: this is a layer of a nodule sample.
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Fe_ppm
Attribute_Definition: Iron concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 78900
Range_Domain_Maximum: 195300
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Mn_ppm
Attribute_Definition: Manganese concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 78100
Range_Domain_Maximum: 301400
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Si_ppm
Attribute_Definition: Silicon concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 7100
Range_Domain_Maximum: 135700
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Al_ppm
Attribute_Definition:
Aluminum concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1300
Range_Domain_Maximum: 43600
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Mg_ppm
Attribute_Definition: Magnesium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 7600
Range_Domain_Maximum: 19400
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Ca_ppm
Attribute_Definition: Calcium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 9800
Range_Domain_Maximum: 124400
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Na_ppm
Attribute_Definition: Sodium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 3900
Range_Domain_Maximum: 19400
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: K_ppm
Attribute_Definition: Potassium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 400
Range_Domain_Maximum: 12600
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Ti_ppm
Attribute_Definition: Titanium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 4700
Range_Domain_Maximum: 15060
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: P_ppm
Attribute_Definition: Phosphorus concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1800
Range_Domain_Maximum: 42700
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: S_ppm
Attribute_Definition:
Sulfur concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1200
Range_Domain_Maximum: 4 830
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: LOI_ppm
Attribute_Definition: Loss on ignition when heated to 1000 C for each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 143700
Range_Domain_Maximum: 351700
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 100
Attribute:
Attribute_Label: H2O M_ppm
Attribute_Definition: Quantity of H2O-, or sorbed water, in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 64900
Range_Domain_Maximum: 259600
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 100
Attribute:
Attribute_Label: H2OP_ppm
Attribute_Definition:
Quantity of H2O+, or structural water, in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 82000
Range_Domain_Maximum: 214000
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1000
Attribute:
Attribute_Label: Ag_ppm
Attribute_Definition:
Silver concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.03
Range_Domain_Maximum: 0.74
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: As_ppm
Attribute_Definition: Arsenic concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 114.7
Range_Domain_Maximum: 330.7
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Ba_ppm
Attribute_Definition: Barium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 806
Range_Domain_Maximum: 4726
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Be_ppm
Attribute_Definition: Beryllium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1.68
Range_Domain_Maximum: 6.51
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Bi_ppm
Attribute_Definition: Bismuth concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 13.68
Range_Domain_Maximum: 130.25
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Cd_ppm
Attribute_Definition: Cadmium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2.18
Range_Domain_Maximum: 10.61
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Co_ppm
Attribute_Definition:
Cobalt concentration in each sample. Values of -7777 indicate that the measurement was above the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1872.4
Range_Domain_Maximum: 10095.4
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Cr_ppm
Attribute_Definition: Chromium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 8
Range_Domain_Maximum: 391
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Cs_ppm
Attribute_Definition: Cesium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.1
Range_Domain_Maximum: 1.4
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Cu_ppm
Attribute_Definition: Copper concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 286
Range_Domain_Maximum: 2429
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Ge_ppm
Attribute_Definition:
Germanium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit, and values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.16
Range_Domain_Maximum: 0.46
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Hf_ppm
Attribute_Definition:
Hafnium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1.6
Range_Domain_Maximum: 10.3
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Hg_ppm
Attribute_Definition:
Mercury concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.006
Range_Domain_Maximum: 0.008
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.001
Attribute:
Attribute_Label: In_ppm
Attribute_Definition: Indium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.110
Range_Domain_Maximum: 0.515
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.001
Attribute:
Attribute_Label: Li_ppm
Attribute_Definition: Lithium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1.0
Range_Domain_Maximum: 74.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Mo_ppm
Attribute_Definition: Molybdenum concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 121.62
Range_Domain_Maximum: 1422.51
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Nb_ppm
Attribute_Definition: Niobium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 31.8
Range_Domain_Maximum: 54.3
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Ni_ppm
Attribute_Definition:
Nickel concentration in each sample. Values of -7777 indicate that the measurement was above the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2630
Range_Domain_Maximum: 10174
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Pb_ppm
Attribute_Definition: Lead concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 627.6
Range_Domain_Maximum: 2848.2
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Rb_ppm
Attribute_Definition: Rubidium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 3
Range_Domain_Maximum: 32
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Re_ppm
Attribute_Definition:
Rubidium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.002
Range_Domain_Maximum: 0.026
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.001
Attribute:
Attribute_Label: Sb_ppm
Attribute_Definition: Antimony concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 29.4
Range_Domain_Maximum: 64.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Sc_ppm
Attribute_Definition: Scandium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 3.5
Range_Domain_Maximum: 14.6
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Se_ppm
Attribute_Definition:
Selenium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit, and values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: -8888
Enumerated_Domain_Value_Definition:
Values of -8888 indicate that the measurement was below the detection limit.
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: -9999
Enumerated_Domain_Value_Definition: Values of -9999 indicate that no analysis was performed.
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sn_ppm
Attribute_Definition: Tin concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1.6
Range_Domain_Maximum: 11.5
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Sr_ppm
Attribute_Definition: Strontium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 597.5
Range_Domain_Maximum: 2075.9
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Ta_ppm
Attribute_Definition:
Tantalum concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.12
Range_Domain_Maximum: 1.56
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Te_ppm
Attribute_Definition: Tellurium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 14.30
Range_Domain_Maximum: 102.00
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Th_ppm
Attribute_Definition: Thorium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 6.22
Range_Domain_Maximum: 57.53
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Tl_ppm
Attribute_Definition: Thallium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 12.07
Range_Domain_Maximum: 231.23
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: U_ppm
Attribute_Definition: Uranium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 4.72
Range_Domain_Maximum: 18.26
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: V_ppm
Attribute_Definition: Vanadium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 293
Range_Domain_Maximum: 852
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: W_ppm
Attribute_Definition: Tungsten concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 34.3
Range_Domain_Maximum: 170.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Zn_ppm
Attribute_Definition: Zinc concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 434
Range_Domain_Maximum: 1008
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Zr_ppm
Attribute_Definition: Zirconium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 21
Range_Domain_Maximum: 618
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: La_ppm
Attribute_Definition: Lanthanum concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 111.57
Range_Domain_Maximum: 417.21
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Ce_ppm
Attribute_Definition: Cerium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 339.51
Range_Domain_Maximum: 1904.76
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Pr_ppm
Attribute_Definition: Praseodymium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 22.11
Range_Domain_Maximum: 92.90
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Nd_ppm
Attribute_Definition: Neodyium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 93.12
Range_Domain_Maximum: 390.03
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Sm_ppm
Attribute_Definition: Samarium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 18.87
Range_Domain_Maximum: 85.69
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Eu_ppm
Attribute_Definition: Europium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 4.68
Range_Domain_Maximum: 20.33
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Gd_ppm
Attribute_Definition: Gadolinium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 18.14
Range_Domain_Maximum: 81.91
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Tb_ppm
Attribute_Definition: Terbium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2.64
Range_Domain_Maximum: 12.88
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Dy_ppm
Attribute_Definition: Dysprosium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 15.30
Range_Domain_Maximum: 75.76
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.1
Attribute:
Attribute_Label: Y_ppm
Attribute_Definition: Yttrium content in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 55.60
Range_Domain_Maximum: 487.60
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Ho_ppm
Attribute_Definition: Holmium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2.91
Range_Domain_Maximum: 14.30
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Er_ppm
Attribute_Definition: Erbium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 8.12
Range_Domain_Maximum: 40.06
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Tm_ppm
Attribute_Definition: Thulium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1.126
Range_Domain_Maximum: 5.564
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.001
Attribute:
Attribute_Label: Yb_ppm
Attribute_Definition: Ytterbium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 7.42
Range_Domain_Maximum: 35.98
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.01
Attribute:
Attribute_Label: Lu_ppm
Attribute_Definition: Lutetium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1.210
Range_Domain_Maximum: 6.112
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.001
Attribute:
Attribute_Label: SUM_REY
Attribute_Definition:
Summation of the concentration of rare earth elements (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) plus Y in each sample
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 896
Range_Domain_Maximum: 2921
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Percent_HREY
Attribute_Definition:
Percentage of the heavy rare earth elements calculated by taking the sum of heavy rare earth elements (Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) and Y and dividing by the SUM_REY for each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 10
Range_Domain_Maximum: 39
Attribute_Units_of_Measure: percent
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Au_ppm
Attribute_Definition:
Gold concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit, and values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.004
Range_Domain_Maximum: 0.027
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.001
Attribute:
Attribute_Label: Ir
Attribute_Definition:
Iridium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.012
Range_Domain_Maximum: 0.034
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.001
Attribute:
Attribute_Label: Os
Attribute_Definition:
Osmium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit, and values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: -8888
Enumerated_Domain_Value_Definition:
Values of -8888 indicate that the measurement was below the detection limit.
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: -9999
Enumerated_Domain_Value_Definition: Values of -9999 indicate that no analysis was performed.
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Pd
Attribute_Definition:
Palladium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.006
Range_Domain_Maximum: 0.083
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.001
Attribute:
Attribute_Label: Pt
Attribute_Definition:
Platinum concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.126
Range_Domain_Maximum: 0.561
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.001
Attribute:
Attribute_Label: Rh
Attribute_Definition:
Rhenium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.008
Range_Domain_Maximum: 0.041
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.001
Attribute:
Attribute_Label: Ru
Attribute_Definition:
Ruthenium concentration in each sample. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 0.006
Range_Domain_Maximum: 0.033
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 0.001
Attribute:
Attribute_Label: Fe_Detection_ppm
Attribute_Definition:
The lower detection limit for iron concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Mn_Detection_ppm
Attribute_Definition:
The lower detection limit for manganese concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Si_Detection_ppm
Attribute_Definition:
The lower detection limit for silicon concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Al_Detection_ppm
Attribute_Definition:
The lower detection limit for aluminum concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Mg_Detection_ppm
Attribute_Definition:
The lower detection limit for magnesium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ca_Detection_ppm
Attribute_Definition:
The lower detection limit for calcium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Na_Detection_ppm
Attribute_Definition:
The lower detection limit for sodium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: K_Detection_ppm
Attribute_Definition:
The lower detection limit for potassium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ti_Detection_ppm
Attribute_Definition:
The lower detection limit for titanium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: P_Detection_ppm
Attribute_Definition:
The lower detection limit for phosphorus concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: S_Detection_ppm
Attribute_Definition:
The lower detection limit for sulfur concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: LOI_Detection_ppm
Attribute_Definition:
The lower detection limit for loss on ignition based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: H2OM_Detection_ppm
Attribute_Definition:
The lower detection limit for H2OM, or sorbed water, concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: H2OP_Detection_ppm
Attribute_Definition:
The lower detection limit for H2OP, or structural water, concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ag_Detection_ppm
Attribute_Definition:
The lower detection limit for silver concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: As_Detection_ppm
Attribute_Definition:
The lower detection limit for arsenic concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ba_Detection_ppm
Attribute_Definition:
The lower detection limit for barium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Be_Detection_ppm
Attribute_Definition:
The lower detection limit for beryllium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Bi_Detection_ppm
Attribute_Definition:
The lower detection limit for bismuth concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Cd_Detection_ppm
Attribute_Definition:
The lower detection limit for cadmium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Co_Detection_ppm
Attribute_Definition:
The lower detection limit for cobalt concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Cr_Detection_ppm
Attribute_Definition:
The lower detection limit for chromium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Cs_Detection_ppm
Attribute_Definition:
The lower detection limit for cesium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Cu_Detection_ppm
Attribute_Definition:
The lower detection limit for copper concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ge_Detection_ppm
Attribute_Definition:
The lower detection limit for germanium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Hf_Detection_ppm
Attribute_Definition:
The lower detection limit for hafnium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Hg_Detection_ppm
Attribute_Definition:
The lower detection limit for mercury concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: In_Detection_ppm
Attribute_Definition:
The lower detection limit for indium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Li_Detection_ppm
Attribute_Definition:
The lower detection limit for lithium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Mo_Detection_ppm
Attribute_Definition:
The lower detection limit for molybdenum concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Nb_Detection_ppm
Attribute_Definition:
The lower detection limit for niobium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ni_Detection_ppm
Attribute_Definition:
The lower detection limit for nickel concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Pb_Detection_ppm
Attribute_Definition:
The lower detection limit for lead concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Rb_Detection_ppm
Attribute_Definition:
The lower detection limit for rubidium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Re_Detection_ppm
Attribute_Definition:
The lower detection limit for rhenium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sb_Detection_ppm
Attribute_Definition:
The lower detection limit for antimony concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sc_Detection_ppm
Attribute_Definition:
The lower detection limit for scandium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Se_Detection_ppm
Attribute_Definition:
The lower detection limit for selenium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sn_Detection_ppm
Attribute_Definition:
The lower detection limit for tin concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sr_Detection_ppm
Attribute_Definition:
The lower detection limit for strontium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ta_Detection_ppm
Attribute_Definition:
The lower detection limit for tantalum concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Te_Detection_ppm
Attribute_Definition:
The lower detection limit for tellurium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Th_Detection_ppm
Attribute_Definition:
The lower detection limit for thorium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Tl_Detection_ppm
Attribute_Definition:
The lower detection limit for thallium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: U_Detection_ppm
Attribute_Definition:
The lower detection limit for uranium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: V_Detection_ppm
Attribute_Definition:
The lower detection limit for vanadium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: W_Detection_ppm
Attribute_Definition:
The lower detection limit for tungsten concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Zn_Detection_ppm
Attribute_Definition:
The lower detection limit for zinc concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Zr_Detection_ppm
Attribute_Definition:
The lower detection limit for zirconium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: La_Detection_ppm
Attribute_Definition:
The lower detection limit for lanthanum concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ce_Detection_ppm
Attribute_Definition:
The lower detection limit for cerium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Pr_Detection_ppm
Attribute_Definition:
The lower detection limit for praseodymium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Nd_Detection_ppm
Attribute_Definition:
The lower detection limit for neodymium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sm_Detection_ppm
Attribute_Definition:
The lower detection limit for samarium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Eu_Detection_ppm
Attribute_Definition:
The lower detection limit for europium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Gd_Detection_ppm
Attribute_Definition:
The lower detection limit for gadolinium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Tb_Detection_ppm
Attribute_Definition:
The lower detection limit for terbium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Dy_Detection_ppm
Attribute_Definition:
The lower detection limit for dysprosium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Y_Detection_ppm
Attribute_Definition:
The lower detection limit for yttrium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ho_Detection_ppm
Attribute_Definition:
The lower detection limit for holmium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Er_Detection_ppm
Attribute_Definition:
The lower detection limit for erbium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Tm_Detection_ppm
Attribute_Definition:
The lower detection limit for thulium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Yb_Detection_ppm
Attribute_Definition:
The lower detection limit for ytterbium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Lu_Detection_ppm
Attribute_Definition:
The lower detection limit for lutetium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Au_Detection_ppm
Attribute_Definition:
The lower detection limit for gold concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ir_Detection
Attribute_Definition:
The lower detection limit for iridium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Os_Detection
Attribute_Definition:
The lower detection limit for osmium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Pd_Detection
Attribute_Definition:
The lower detection limit for palladium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Pt_Detection
Attribute_Definition:
The lower detection limit for platinum concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Rh_Detection
Attribute_Definition:
The lower detection limit for rhodium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ru_Detection
Attribute_Definition:
The lower detection limit for ruthenium concentration based on the measurement method and instrumentation. Values of -9999 indicate that the detection limit was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Fe_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure iron concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-XRF
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Mn_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure manganese concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-XRF
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Si_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure silicon concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-XRF
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Al_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure aluminum concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-XRF
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Mg_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure magnesium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-XRF
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ca_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure calcium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-XRF
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Na_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure sodium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-XRF
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: K_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure potassium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-XRF
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ti_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure titanium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-XRF
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: P_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure phosphorus concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-XRF
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / XRF by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: S_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure sulfur concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-ICP
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: LOI_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure loss on ignition.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: GRAV
Enumerated_Domain_Value_Definition: Gravimetric by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: H2OM_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure H2O-, or sorbed water, concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: GRAV-Moisture
Enumerated_Domain_Value_Definition: Gravimetric and IR by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: H2OP_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure H2O+, or structural water, concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: H2O+
Enumerated_Domain_Value_Definition: Infrared by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ag_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure silver concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: As_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure aresenic concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition:
Instrumental Neutron Activation Analysis by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ba_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure barium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Be_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure beryllium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Bi_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure bismuth concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Cd_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure cadmium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Co_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure cobalt concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Cr_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure chromium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-ICP
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Cs_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure cesium concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Cu_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure copper concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ge_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure germanium concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Hf_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure hafnium concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Hg_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure mercury concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: 1G
Enumerated_Domain_Value_Definition:
Hg Cold Vapour FIMS (PerkinElmer Flow Injection Mercury System) by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: In_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure indium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Li_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure lithium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-ICP
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Optical Emission Spectroscopy, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Mo_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure molybdenum concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Nb_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure niobium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ni_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure nickel concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Pb_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure lead concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Rb_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure rubidium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Re_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure rubidium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sb_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure antimony concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sc_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure scandium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Se_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure selenium concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sn_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure tin concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sr_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure strontium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ta_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure tantalum concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Te_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure tellurium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Th_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure thorium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).v
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Tl_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure thallium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TD-MS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, four-acid digest of hydrochloric, nitric, perchloric and hydrofluoric acids by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: U_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure uranium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: V_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure vanadium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: W_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure tungsten concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Zn_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure zinc concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Zr_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure zirconium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: La_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure lanthanum concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ce_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure cerium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Pr_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure praseodymium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Nd_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure neodymium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sm_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure samarium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Eu_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure europium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Gd_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure gadolinium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Tb_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure terbium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Dy_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure dysprosium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Y_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure yttrium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ho_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure holmium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).v
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Er_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure erbium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Tm_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure thulium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Yb_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure ytterbium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Lu_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure lutetium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: FUS-MS
Enumerated_Domain_Value_Definition:
Lithium Borate Fusion / Inductively Coupled Plasma Mass Spectrometry by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Au_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure gold concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition:
Instrumental Neutron Activation Analysis by Activation Laboratories Ltd. (Actlabs).
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NS25H/MS
Enumerated_Domain_Value_Definition:
Fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) by Intertek analytical labs
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ir_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure iridium concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NS25H/MS
Enumerated_Domain_Value_Definition:
Fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) by Intertek analytical labs
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Os_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure osmium concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NS25H/MS
Enumerated_Domain_Value_Definition:
Fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) by Intertek analytical labs
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Pd_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure palladium concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NS25H/MS
Enumerated_Domain_Value_Definition:
Fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) by Intertek analytical labs
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Pt_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure platinum concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NS25H/MS
Enumerated_Domain_Value_Definition:
Fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) by Intertek analytical labs
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Rh_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure rhodium concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NS25H/MS
Enumerated_Domain_Value_Definition:
Fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) by Intertek analytical labs
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ru_Method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure ruthenium concentration. NaN indicates that method information was not available.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: NS25H/MS
Enumerated_Domain_Value_Definition:
Fire assay nickel sulfide collection and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) by Intertek analytical labs
Enumerated_Domain_Value_Definition_Source: producer defined