Geochemistry of sediment subsamples from gravity cores and push cores from the Escanaba Trough (Gorda Ridge)

Metadata also available as - [Questions & Answers] - [Parseable text] - [XML]

Metadata:

Identification_Information:
Citation:
Citation_Information:
Originator: Katlin Bowman Adamczyk
Originator: Amy Gartman
Originator: Jaycee Favela
Originator: Jacob Tidwell
Publication_Date: 20250317
Title:
Geochemistry of sediment subsamples from gravity cores and push cores from the Escanaba Trough (Gorda Ridge)
Geospatial_Data_Presentation_Form: comma-delimited text
Series_Information:
Series_Name: data release
Issue_Identification: DOI:10.5066/P13B46QX
Publication_Information:
Publication_Place:
Pacific Coastal and Marine Science Center, Santa Cruz, California
Publisher: U.S. Geological Survey
Online_Linkage: https://doi.org/10.5066/P13B46QX
Online_Linkage: Larger_Work_Citation:
Citation_Information:
Originator: Katlin Bowman Adamczyk
Originator: Amy Gartman
Originator: Jaycee Favela
Originator: Jacob Tidwell
Publication_Date: 2025
Title:
Computed tomography (CT) scans, photographs, geochemistry, grain-size analysis, X-ray fluorescence (XRF) scans, X-ray diffraction (XRD), magnetic susceptibility, and gamma-ray bulk density data of gravity cores and push cores from the Escanaba Trough (Gorda Ridge)
Series_Information:
Series_Name: data release
Issue_Identification: DOI:10.5066/P13B46QX
Publication_Information:
Publication_Place: Pacific Coastal and Marine Science Center, Santa Cruz, CA
Publisher: U.S. Geological Survey
Other_Citation_Details:
Suggested Citation: Adamczyk, K., Gartman, A., Favela, J., and Tidwell, J., 2025, Computed tomography (CT) scans, photographs, geochemistry, grain-size analysis, X-ray fluorescence (XRF) scans, X-ray diffraction (XRD), magnetic susceptibility, and gamma-ray bulk density data of gravity cores and push cores from the Escanaba Trough (Gorda Ridge): U.S. Geological Survey data release, https://doi.org/10.5066/P13B46QX.
Online_Linkage: https://doi.org/10.5066/P13B46QX
Online_Linkage:
Description:
Abstract:
This portion of the data release contains geochemical data of sediment subsamples from push cores and gravity cores collected from the Escanaba Trough vent field, Gorda Ridge, in the northeast Pacific Ocean. These data were collected in 2022 (USGS Field Activity 2022-621-FA). Data include major, minor, and trace element concentrations, location information (latitude, longitude, depth), analytical methods, and instrument detection limits where available.
Purpose:
Data were obtained to characterize downcore geochemical properties of sediments. These data are intended for science researchers, students, policy makers, and the general public.
Supplemental_Information:
Additional information about the field activity or activities from which these data were derived is available online at:
https://cmgds.marine.usgs.gov/fan_info.php?fan=2022-621-FA
Any use of trade, product, or firm names is for descriptive purposes only and does not imply endorsement by the U.S. Government.
Time_Period_of_Content:
Time_Period_Information:
Range_of_Dates/Times:
Beginning_Date: 20220712
Ending_Date: 20231129
Currentness_Reference: Time data were compiled to completion of the last process step
Status:
Progress: Complete
Maintenance_and_Update_Frequency: None planned
Spatial_Domain:
Bounding_Coordinates:
West_Bounding_Coordinate: -127.5357
East_Bounding_Coordinate: -127.4076
North_Bounding_Coordinate: 41.1632
South_Bounding_Coordinate: 40.6957
Keywords:
Theme:
Theme_Keyword_Thesaurus: ISO 19115 Topic Category
Theme_Keyword: oceans
Theme_Keyword: geoscientificInformation
Theme:
Theme_Keyword_Thesaurus: Data Categories for Marine Planning
Theme_Keyword: Nonliving Resources
Theme_Keyword: Material Resources
Theme_Keyword: Mineral Resources
Theme_Keyword: Physical/Chemical Features
Theme:
Theme_Keyword_Thesaurus: USGS Thesaurus
Theme_Keyword: push coring
Theme_Keyword: gravity coring
Theme_Keyword: chemical analysis
Theme_Keyword: mass spectroscopy
Theme_Keyword: geochemistry
Theme_Keyword: metallic mineral resources
Theme_Keyword: earth sciences
Theme_Keyword: marine geology
Theme:
Theme_Keyword_Thesaurus: Marine Realms Information Bank (MRIB) keywords
Theme_Keyword: sediment geochemistry
Theme_Keyword: mineral resources
Theme_Keyword: chemical analysis
Theme:
Theme_Keyword_Thesaurus: None
Theme_Keyword: U.S. Geological Survey
Theme_Keyword: USGS
Theme_Keyword: Coastal and Marine Hazards and Resources Program
Theme_Keyword: CMHRP
Theme_Keyword: Pacific Coastal and Marine Science Center
Theme_Keyword: PCMSC
Theme_Keyword: Global Ocean Mineral Resources
Theme:
Theme_Keyword_Thesaurus: USGS Metadata Identifier
Theme_Keyword: USGS:670957a2d34e969edc5a2a9b
Place:
Place_Keyword_Thesaurus: Geographic Names Information System (GNIS)
Place_Keyword: Pacific Ocean
Place:
Place_Keyword_Thesaurus: NGA GEOnet Names Server (GNS)
Place_Keyword: Escanaba Trough
Place_Keyword: Gorda Ridge
Access_Constraints: No access constraints
Use_Constraints:
USGS-authored or produced data and information are in the public domain from the U.S. Government and are freely redistributable with proper metadata and source attribution. Please recognize and acknowledge the U.S. Geological Survey as the originator of the dataset and in products derived from these data.
Point_of_Contact:
Contact_Information:
Contact_Organization_Primary:
Contact_Organization:
U.S. Geological Survey, Pacific Coastal and Marine Science Center
Contact_Person: PCMSC Science Data Coordinator
Contact_Address:
Address_Type: mailing and physical
Address: 2885 Mission Street
City: Santa Cruz
State_or_Province: CA
Postal_Code: 95060
Contact_Voice_Telephone: 831-427-4747
Contact_Electronic_Mail_Address: pcmsc_data@usgs.gov
Browse_Graphic:
Browse_Graphic_File_Name: Browse_Graphic_File_Description: Push core sediment collection with a remotely operated vehicle.
Browse_Graphic_File_Type: JPEG
Data_Set_Credit:
Exploring the Seafloor and Oceanic Footprints is an interagency effort involving the National Oceanic and Atmospheric Administration, the U.S. Geological Survey, and the Bureau of Ocean Energy Management. Funding is acknowledged from NOAA Ocean Exploration via its Ocean Exploration Fiscal Year 2019 Funding Opportunity and through the National Oceanographic Partnership Program (NOPP), from the USGS Coastal and Marine Hazards and Resources Enhanced Funding Opportunities, and from the Bureau of Ocean Energy Management through Interagency Agreement M19PG00021 with the United States Geological Survey.
Native_Data_Set_Environment: Windows 11 Enterprise, Microsoft Excel 365 for enterprise
Data_Quality_Information:
Attribute_Accuracy:
Attribute_Accuracy_Report:
Certified reference materials, including PACS-3 (marine sediment certified by National Research Council Canada), were measured for all reported elements except Ag, B, Br, Cr, Ge, Ir, Lu, Na, Sc. The average relative percent difference (RPD) between measured and certified concentrations was 10–20 percent for Dy, Ta, Sr, Ni, Se, W, and Tm. Higher RPDs (>20 percent) were observed for Be and Hf. Average RPDs were <10 percent for Al, As, Au, Ba, Bi, Ca, Cd, Ce, Co, Cs, Cu, Er, Eu, Fe, Ga, Gd, Hg, Ho, In, K, La, Li, Mg, Mn, Mo, Nb, Nd, Pb, Pr, Rb, S, Sb, Si, Sm, Sn, Tb, Te, Th, Ti, Tl, U, V, Y, Yb, Zn, Zr. Duplicate measurements were made for all elements except Ag, B, Br, Cr, Ge, Ir, Lu, Na, and Sc. The average RPD between duplicate measurements was 10–20 percent for Dy, Ta, Sr, Ni, Se, W, Tm. Higher RPDs (>20 percent) were observed for Be and Hf. Average RPDs were <10 percent for Al, As, Au, Ba, Bi, Ca, Cd, Ce, Co, Cs, Cu, Er, Eu, Fe, Ga, Gd, Hg, Ho, In, K, La, Li, Mg, Mn, Mo, Nb, Nd, Pb, Pr, Rb, S, Sb, Si, Sm, Sn, Tb, Te, Th, Ti, Tl, U, V, Y, Yb, Zn, and Zr. The instruments and techniques used to generate the geochemical data are included in the data table and also summarized below in a Source Citation since data were generated by a commercial laboratory. Limits for each analyte's detection by an instrument are reported in the table. The value -8888 indicates that the measurement for an analyte was below the detection limit and the value -7777 indicates that the measurement for an analyte was above the detection limit.
Logical_Consistency_Report: No formal logical accuracy tests were conducted.
Completeness_Report:
Dataset is considered complete for the information presented, as described in the abstract. Users are advised to read the rest of the metadata record carefully for additional details.
Positional_Accuracy:
Horizontal_Positional_Accuracy:
Horizontal_Positional_Accuracy_Report:
The locations of push core samples were determined using ROV Jason’s ultra-short baseline (USBL) navigation. Accuracy for this depth is approximately 6-26 m. The locations of gravity core samples were determined using the R/V Thomas G. Thompson’s GPS navigation, which is accurate to less than 5 m. A formal accuracy assessment of the horizontal positional information in the dataset has not been conducted.
Vertical_Positional_Accuracy:
Vertical_Positional_Accuracy_Report:
For push core samples, the vertical accuracy was determined with ROV Jason’s altimeter, which is accurate to less than 1 m. For gravity core samples, the vertical accuracy was determined with the R/V Thomas G. Thompson’s multibeam bathymetry system. No formal positional accuracy tests were conducted.
Lineage:
Source_Information:
Source_Citation:
Citation_Information:
Originator: Adamczyk, Katlin
Originator: Gartman, Amy
Originator: Favela, Jaycee
Originator: Tidwell, Jacob
Publication_Date: 2025
Title:
Location and water depth for gravity cores and push cores from the Escanaba Trough (Gorda Ridge)
Geospatial_Data_Presentation_Form: comma-delimited text
Publication_Information:
Publication_Place: online
Publisher: U.S. Geological Survey
Online_Linkage:
Type_of_Source_Media: U.S. Geological Survey data release
Source_Time_Period_of_Content:
Time_Period_Information:
Range_of_Dates/Times:
Beginning_Date: 20220524
Ending_Date: 20220613
Source_Currentness_Reference: ground condition at time samples were collected
Source_Citation_Abbreviation: TN403_CoreLocations
Source_Contribution:
Latitude, longitude, and water depth information for gravity cores and push cores from this same data release
Source_Information:
Source_Citation:
Citation_Information:
Originator: Actlabs, Ancaster, Ontario, Canada
Publication_Date: 2022
Title: Geochemical Element Analysis
Online_Linkage: https://actlabs.com/geochemistry/
Type_of_Source_Media: geochemical analyses
Source_Time_Period_of_Content:
Time_Period_Information:
Single_Date/Time:
Calendar_Date: 20220712
Source_Currentness_Reference: Date that official lab reports were released by Actlabs
Source_Citation_Abbreviation: geochemistry
Source_Contribution:
Geochemical analysis of sediment with Inductively Coupled Plasma Mass Spectrometry (sodium peroxide or lithium borate fusion), Instrumental Neutron Activation Analysis, and Cold Vapor Atomic Absorption Spectroscopy techniques.
Process_Step:
Process_Description:
Push core and gravity core samples were collected on the R/V Thomas G. Thompson between May 24, 2022, and June 13, 2022, during the TN403 Escanaba Trough expedition, which was led and staffed by USGS employees. Push cores were pushed into sediment at 37 locations by ROV Jason’s manipulator arm in water depths between 3201 and 3301 meters. Gravity cores were collected using a gravity corer at 7 locations in water depths between 3209 and 3304 meters. Gravity cores greater than 60 cm in length were cut into sections onboard the ship and labeled ‘X’ (0-60 cm), ‘Y’ (60-120 cm), and ‘Z’ (>120 cm). All cores were stored upright and refrigerated until return to shore.
Process_Date: 20220613
Process_Step:
Process_Description:
In the USGS Pacific Coastal and Marine Science Center (PCMSC) Core Preparation and Analysis Laboratory, subsamples were collected from relevant stratigraphic regions of the core. Pelagic clay and organic-rich sediments were air-dried and sulfidic sediments were dried in a glove bag purged with nitrogen gas. Dried sediment was ground to a powder using a mortar and pestle.
Process_Date: 20220620
Process_Step:
Process_Description:
Approximately 10 grams of each sample was mailed to ACTLabs in individual plastic screw-top containers. All geochemical analyses were performed by ActLabs.
Process_Date: 20220625
Process_Step:
Process_Description:
Results from lab analyses, detection limits, analytical method information, location data, cruise identification, and location data were combined into a comma-delimited text value document (TN403_SedimentGeochemistry.csv).
Source_Used_Citation_Abbreviation: TN403_CoreLocations
Source_Used_Citation_Abbreviation: geochemistry
Process_Date: 20231129
Process_Contact:
Contact_Information:
Contact_Person_Primary:
Contact_Person: Katlin Adamczyk
Contact_Organization: USGS
Contact_Position: Physical Scientist
Contact_Address:
Address_Type: mailing and physical
Address: 2885 Mission Street
City: Santa Cruz
State_or_Province: CA
Postal_Code: 95060
Contact_Voice_Telephone: 831-460-7420
Contact_Electronic_Mail_Address: kadamczyk@usgs.gov
Spatial_Data_Organization_Information:
Direct_Spatial_Reference_Method: Point
Point_and_Vector_Object_Information:
SDTS_Terms_Description:
SDTS_Point_and_Vector_Object_Type: Point
Point_and_Vector_Object_Count: 78
Spatial_Reference_Information:
Horizontal_Coordinate_System_Definition:
Geographic:
Latitude_Resolution: 0.0001
Longitude_Resolution: 0.0001
Geographic_Coordinate_Units: Decimal degrees
Geodetic_Model:
Horizontal_Datum_Name: D_WGS_1984
Ellipsoid_Name: WGS_1984
Semi-major_Axis: 6378137.0
Denominator_of_Flattening_Ratio: 298.257222101
Entity_and_Attribute_Information:
Detailed_Description:
Entity_Type:
Entity_Type_Label: TN403_SedimentGeochemistry.csv
Entity_Type_Definition:
Comma-delimited file containing results from geochemical analyses of marine sediment samples at the latitude, longitude, and water depth of each sample location. The value -8888 indicates that the measurement for an analyte was below the detection limit, and the value of -7777 indicates that the measurement for an analyte was above the detection limit.
Entity_Type_Definition_Source: Producer defined
Attribute:
Attribute_Label: Cruise_ID
Attribute_Definition:
The alphanumeric cruise identifier for the expedition during which the sample was collected
Attribute_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: TN403
Enumerated_Domain_Value_Definition:
Cruise identifier for the Escanaba Trough expedition onboard the R/V Thomas G. Thompson in 2022
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sample_ID
Attribute_Definition: The sample ID for each sample
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain:
Sample IDs for gravity cores are formatted as GC#-section (for example, GC08-X is gravity core 08 section X). Gravity core sections are 'X' (0-60 cm), 'Y' (60-120 cm), and 'Z' (>120 cm). Sample IDs for push cores are formatted as Dive#-PushCore# (for example, J2-1418-PC03 is ROV Jason dive number J2-1418, push core number 03).
Attribute:
Attribute_Label: Subsample_Depth_Interval
Attribute_Definition: The subsample depth interval for each sample
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain:
The depth interval, measured in centimeters from the top of the sediment-water interface in push cores and gravity core 'X' sections, or the top of the core liner for gravity core 'Y' and 'Z' sections. For example, GC06-Z-0–2 represents 0–2 cm in section Z of gravity core 06; 0 cm here is the top of section Z, not the sediment-water interface of the entire gravity core. Text appended after the sediment depth interval (such as _brown) are notable color descriptions of the material.
Attribute:
Attribute_Label: Latitude
Attribute_Definition: Latitude at which sample was collected
Attribute_Definition_Source: TN403_CoreLocations
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 40.6957
Range_Domain_Maximum: 41.1632
Attribute_Units_of_Measure: decimal degrees
Attribute_Measurement_Resolution: .0001
Attribute:
Attribute_Label: Longitude
Attribute_Definition: Longitude at which sample was collected
Attribute_Definition_Source: TN403_CoreLocations
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: -127.5357
Range_Domain_Maximum: -127.4076
Attribute_Units_of_Measure: decimal degrees
Attribute_Measurement_Resolution: .0001
Attribute:
Attribute_Label: Water_Depth
Attribute_Definition: Water depth in meters at which the sample was collected
Attribute_Definition_Source: TN403_CoreLocations
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 3201
Range_Domain_Maximum: 3304
Attribute_Units_of_Measure: meters
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Fe
Attribute_Definition: Iron concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 34300
Range_Domain_Maximum: 562000
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Mn
Attribute_Definition:
Manganese concentration in each sample. Values of -7777 indicate that the measurement was above the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 29
Range_Domain_Maximum: 34200
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Si
Attribute_Definition:
Silicon concentration in each sample. Values of -7777 indicate that the measurement was above the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1700
Range_Domain_Maximum: 305000
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Al
Attribute_Definition: Aluminum concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 500
Range_Domain_Maximum: 87900
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Mg
Attribute_Definition: Magnesium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 700
Range_Domain_Maximum: 84800
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Ca
Attribute_Definition: Calcium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 300
Range_Domain_Maximum: 24400
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Na
Attribute_Definition: Sodium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 3600
Range_Domain_Maximum: 38300
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: K
Attribute_Definition:
Potassium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 3000
Range_Domain_Maximum: 25000
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Ti
Attribute_Definition:
Titanium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 100
Range_Domain_Maximum: 4800
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: S
Attribute_Definition:
Sulfur concentration in each sample. Values of -7777 indicate that the measurement was above the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1100
Range_Domain_Maximum: 364000
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Ag
Attribute_Definition:
Silver concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry.
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 16
Range_Domain_Maximum: 35
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: As
Attribute_Definition:
Arsenic concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2.0
Range_Domain_Maximum: 5750.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: B
Attribute_Definition:
Boron concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 10
Range_Domain_Maximum: 300
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Ba
Attribute_Definition: Barium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 500
Range_Domain_Maximum: 64800
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Be
Attribute_Definition:
Beryllium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Unrepresentable_Domain:
Values of -8888 indicate that the measurement was below the detection limit (<3 ppm).
Attribute:
Attribute_Label: Bi
Attribute_Definition:
Bismuth concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2
Range_Domain_Maximum: 314
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Br
Attribute_Definition: Bromine concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 24.5
Range_Domain_Maximum: 242.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Cd
Attribute_Definition:
Cadmium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2
Range_Domain_Maximum: 32
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Co
Attribute_Definition: Cobalt concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 5
Range_Domain_Maximum: 981
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Cr
Attribute_Definition:
Chromium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 15
Range_Domain_Maximum: 209
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Cs
Attribute_Definition: Caesium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .1
Range_Domain_Maximum: 10.2
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Cu
Attribute_Definition:
Copper concentration in each sample. Values of -7777 indicate that the measurement was above the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 23
Range_Domain_Maximum: 18400
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Ga
Attribute_Definition: Gallium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 3.3
Range_Domain_Maximum: 38.9
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Ge
Attribute_Definition: Germanium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .8
Range_Domain_Maximum: 43.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Hf
Attribute_Definition:
Hafnium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1
Range_Domain_Maximum: 6
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Hg
Attribute_Definition: Mercury concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .026
Range_Domain_Maximum: 18.000
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .001
Attribute:
Attribute_Label: In
Attribute_Definition:
Indium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .2
Range_Domain_Maximum: 15.3
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Li
Attribute_Definition:
Lithium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 16
Range_Domain_Maximum: 78
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Mo
Attribute_Definition: Molybdenum concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 3
Range_Domain_Maximum: 152
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Nb
Attribute_Definition:
Niobium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2.4
Range_Domain_Maximum: 16.4
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Ni
Attribute_Definition: Nickel concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 40
Range_Domain_Maximum: 340
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Pb
Attribute_Definition: Lead concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 9.9
Range_Domain_Maximum: 3660.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Rb
Attribute_Definition: Rubidium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1.1
Range_Domain_Maximum: 121.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Sb
Attribute_Definition: Antimony concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .5
Range_Domain_Maximum: 206.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Sc
Attribute_Definition:
Scandium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .6
Range_Domain_Maximum: 19.9
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Se
Attribute_Definition:
Selenium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 8
Range_Domain_Maximum: 370
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Sn
Attribute_Definition: Tin concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1.7
Range_Domain_Maximum: 291.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Sr
Attribute_Definition: Strontium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 95
Range_Domain_Maximum: 1750
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Ta
Attribute_Definition:
Tantalum concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .2
Range_Domain_Maximum: 2.4
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Te
Attribute_Definition:
Tellurium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 7
Range_Domain_Maximum: 17
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Th
Attribute_Definition:
Thorium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .2
Range_Domain_Maximum: 11.1
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Tl
Attribute_Definition: Thallium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .1
Range_Domain_Maximum: 14.7
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: U
Attribute_Definition: Uranium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .9
Range_Domain_Maximum: 47.2
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: V
Attribute_Definition:
Vanadium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 24
Range_Domain_Maximum: 277
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: W
Attribute_Definition:
Tungsten concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .8
Range_Domain_Maximum: 6.7
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Zn
Attribute_Definition:
Zinc concentration in each sample. Values of -7777 indicate that the measurement was above the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 40
Range_Domain_Maximum: 10000
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Zr
Attribute_Definition:
Zirconium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2
Range_Domain_Maximum: 181
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: La
Attribute_Definition: Lanthanum concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 3.6
Range_Domain_Maximum: 34.1
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Ce
Attribute_Definition: Cerium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 4.9
Range_Domain_Maximum: 69.7
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Pr
Attribute_Definition: Praseodymium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .4
Range_Domain_Maximum: 8.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Nd
Attribute_Definition: Neodymium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 1.7
Range_Domain_Maximum: 31.6
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Sm
Attribute_Definition: Samarium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .4
Range_Domain_Maximum: 5.8
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Eu
Attribute_Definition: Europium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .5
Range_Domain_Maximum: 17.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Gd
Attribute_Definition: Gadolinium concentration in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .3
Range_Domain_Maximum: 6.2
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Tb
Attribute_Definition:
Terbium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .1
Range_Domain_Maximum: .8
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Dy
Attribute_Definition:
Dysprosium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .4
Range_Domain_Maximum: 4.8
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Y
Attribute_Definition: Yttrium content in each sample.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .3
Range_Domain_Maximum: 25.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Ho
Attribute_Definition:
Holmium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .2
Range_Domain_Maximum: 1.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Er
Attribute_Definition:
Erbium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .1
Range_Domain_Maximum: 3.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Tm
Attribute_Definition:
Thulium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .1
Range_Domain_Maximum: .4
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Yb
Attribute_Definition:
Ytterbium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .1
Range_Domain_Maximum: 3.0
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .1
Attribute:
Attribute_Label: Lu
Attribute_Definition:
Lutetium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .05
Range_Domain_Maximum: .41
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .01
Attribute:
Attribute_Label: Au
Attribute_Definition:
Gold concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: .006
Range_Domain_Maximum: 3.060
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: .001
Attribute:
Attribute_Label: Ir
Attribute_Definition:
Iridium concentration in each sample. Values of -8888 indicate that the measurement was below the detection limit.
Attribute_Definition_Source: standard reporting value in geochemistry
Attribute_Domain_Values:
Unrepresentable_Domain:
Values of -8888 indicate that the measurement was below the detection limit (<0.005 ppm).
Attribute:
Attribute_Label: Fe_Detection
Attribute_Definition:
The detection limit for iron concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 100
Range_Domain_Maximum: 500
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 100
Attribute:
Attribute_Label: Mn_Detection
Attribute_Definition:
The detection limit for manganese concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 3
Range_Domain_Maximum: 100
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Si_Detection
Attribute_Definition:
The detection limit for silicon concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Al_Detection
Attribute_Definition:
The detection limit for aluminum concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Mg_Detection
Attribute_Definition:
The detection limit for magnesium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ca_Detection
Attribute_Definition:
The detection limit for calcium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Na_Detection
Attribute_Definition:
The detection limit for sodium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: K_Detection
Attribute_Definition:
The detection limit for potassium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ti_Detection
Attribute_Definition:
The detection limit for titanium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: S_Detection
Attribute_Definition:
The detection limit for sulfur concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ag_Detection
Attribute_Definition:
The detection limit for silver concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: As_Detection
Attribute_Definition:
The detection limit for arsenic concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: B_Detection
Attribute_Definition:
The detection limit for boron concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ba_Detection
Attribute_Definition:
The detection limit for barium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Be_Detection
Attribute_Definition:
The detection limit for beryllium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Bi_Detection
Attribute_Definition:
The detection limit for bismuth concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Br_Detection
Attribute_Definition:
The detection limit for bromine concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Cd_Detection
Attribute_Definition:
The detection limit for cadmium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Co_Detection
Attribute_Definition:
The detection limit for cobalt concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Cr_Detection
Attribute_Definition:
The detection limit for chromium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Cs_Detection
Attribute_Definition:
The detection limit for cesium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Cu_Detection
Attribute_Definition:
The detection limit for copper concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Range_Domain:
Range_Domain_Minimum: 2
Range_Domain_Maximum: 50
Attribute_Units_of_Measure: parts per million
Attribute_Measurement_Resolution: 1
Attribute:
Attribute_Label: Ga_Detection
Attribute_Definition:
The detection limit for gallium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ge_Detection
Attribute_Definition:
The detection limit for germanium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Hf_Detection
Attribute_Definition:
The detection limit for hafnium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Hg_Detection
Attribute_Definition:
The detection limit for mercury concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: In_Detection
Attribute_Definition:
The detection limit for indium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Li_Detection
Attribute_Definition:
The detection limit for lithium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Mo_Detection
Attribute_Definition:
The detection limit for molybdenum concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Nb_Detection
Attribute_Definition:
The detection limit for niobium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ni_Detection
Attribute_Definition:
The detection limit for nickel concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Pb_Detection
Attribute_Definition:
The detection limit for lead concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Rb_Detection
Attribute_Definition:
The detection limit for rubidium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sb_Detection
Attribute_Definition:
The detection limit for antimony concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sc_Detection
Attribute_Definition:
The detection limit for scandium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Se_Detection
Attribute_Definition:
The detection limit for selenium concentration based on the measurement method and instrumentation.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sn_Detection
Attribute_Definition:
The detection limit for tin concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sr_Detection
Attribute_Definition:
The detection limit for strontium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ta_Detection
Attribute_Definition:
The detection limit for tantalum concentration based on the measurement method and instrumentation. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Te_Detection
Attribute_Definition:
The detection limit for tellurium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Th_Detection
Attribute_Definition:
The detection limit for thorium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Tl_Detection
Attribute_Definition:
The detection limit for thallium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: U_Detection
Attribute_Definition:
The detection limit for uranium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: V_Detection
Attribute_Definition:
The detection limit for vanadium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: W_Detection
Attribute_Definition:
The detection limit for tungsten concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Zn_Detection
Attribute_Definition:
The detection limit for zinc concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Zr_Detection
Attribute_Definition:
The detection limit for zirconium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: La_Detection
Attribute_Definition:
The detection limit for lanthanum concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ce_Detection
Attribute_Definition:
The detection limit for cerium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Pr_Detection
Attribute_Definition:
The detection limit for praseodymium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Nd_Detection
Attribute_Definition:
The detection limit for neodymium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Sm_Detection
Attribute_Definition:
The detection limit for samarium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Eu_Detection
Attribute_Definition:
The detection limit for europium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Gd_Detection
Attribute_Definition:
The detection limit for gadolinium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Tb_Detection
Attribute_Definition:
The detection limit for terbium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Dy_Detection
Attribute_Definition:
The detection limit for dysprosium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Y_Detection
Attribute_Definition:
The detection limit for yttrium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ho_Detection
Attribute_Definition:
The detection limit for holmium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Er_Detection
Attribute_Definition:
The detection limit for erbium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Tm_Detection
Attribute_Definition:
The detection limit for thulium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Yb_Detection
Attribute_Definition:
The detection limit for ytterbium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Lu_Detection
Attribute_Definition:
The detection limit for lutetium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Au_Detection
Attribute_Definition:
The detection limit for gold concentration based on the measurement method and instrumentation. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Ir_Detection
Attribute_Definition:
The detection limit for iridium concentration based on the measurement method and instrumentation. Values of -9999 indicate that no analysis was performed.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Unrepresentable_Domain: Numerical value provided by the analyzer in parts per million
Attribute:
Attribute_Label: Fe_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure iron concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Mn_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure manganese concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_OES_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Optical Emission Spectroscopy sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Si_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure silicon concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Al_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure aluminum concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Mg_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure magnesium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ca_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure calcium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Na_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure sodium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: K_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure potassium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ti_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure titanium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: S_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure sulfur concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ag_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure silver concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: As_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure arsenic concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: B_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure boron concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ba_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure barium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Be_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure beryllium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Bi_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure bismuth concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Br_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure bromine concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Cd_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure cadmium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Co_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure cobalt concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Cr_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure chromium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Cs_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure caesium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Cu_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure copper concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_OES_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Optical Emission Spectroscopy sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ga_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure gallium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ge_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure germanium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Hf_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure hafnium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Hg_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure mercury concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: CVAAS
Enumerated_Domain_Value_Definition: Cold Vapor Atomic Absorption Spectroscopy
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: In_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure indium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Li_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure lithium concentration based on the measurement method and instrumentation
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Mo_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure molybdenum concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Nb_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure niobium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ni_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure nickel concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Pb_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure lead concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Rb_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure rubidium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sb_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure antimony concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sc_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure scandium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Se_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure selenium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sn_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure tin concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sr_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure strontium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ta_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure tantalum concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Te_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure tellurium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Th_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure thorium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Tl_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure thallium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: U_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure uranium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: V_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure vanadium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: W_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure tungsten concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Zn_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure zinc concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Zr_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure zirconium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_FUS
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry, Lithium Borate Fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: La_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure lanthanum concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ce_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure cerium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Pr_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure praseodymium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Nd_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure neodymium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Sm_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure samarium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Eu_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure europium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Gd_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure gadolinium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Tb_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure terbium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Dy_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure dysprosium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Y_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure yttrium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ho_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure holmium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Er_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure erbium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Tm_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure thulium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Yb_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure ytterbium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: ICP_MS_Na2O2
Enumerated_Domain_Value_Definition:
Inductively Coupled Plasma Mass Spectrometry sodium peroxide fusion
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Lu_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure lutetium concentration
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Au_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure gold concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis
Enumerated_Domain_Value_Definition_Source: producer defined
Attribute:
Attribute_Label: Ir_method
Attribute_Definition:
An alphanumeric code that denotes the method and instrumentation used to measure iridium concentration.
Attribute_Definition_Source: Producer defined
Attribute_Domain_Values:
Enumerated_Domain:
Enumerated_Domain_Value: INAA
Enumerated_Domain_Value_Definition: Instrumental Neutron Activation Analysis
Enumerated_Domain_Value_Definition_Source: producer defined
Overview_Description:
Entity_and_Attribute_Overview: The first line of the csv file is a header line.
Entity_and_Attribute_Detail_Citation: U.S. Geological Survey
Distribution_Information:
Distributor:
Contact_Information:
Contact_Organization_Primary:
Contact_Organization: U.S. Geological Survey - ScienceBase
Contact_Address:
Address_Type: mailing and physical
Address: Denver Federal Center, Building 810, Mail Stop 302
City: Denver
State_or_Province: CO
Postal_Code: 80225
Contact_Voice_Telephone: 1-888-275-8747
Contact_Electronic_Mail_Address: sciencebase@usgs.gov
Resource_Description:
These data are available in .csv format contained in a single file.
Distribution_Liability:
Unless otherwise stated, all data, metadata and related materials are considered to satisfy the quality standards relative to the purpose for which the data were collected. Although these data and associated metadata have been reviewed for accuracy and completeness and approved for release by the U.S. Geological Survey (USGS), no warranty expressed or implied is made regarding the display or utility of the data on any other system or for general or scientific purposes, nor shall the act of distribution constitute any such warranty.
Standard_Order_Process:
Digital_Form:
Digital_Transfer_Information:
Format_Name: comma-delimited text
Format_Version_Number: Microsoft Excel 16.16.17 for Mac
Format_Information_Content: File contains table in .csv format
File_Decompression_Technique: No compression applied
Transfer_Size: .099
Digital_Transfer_Option:
Online_Option:
Computer_Contact_Information: Access_Instructions:
Data and metadata can be downloaded using the Network_Resource_Name links. The first link is a direct link to download a zipped file of data and metadata. The second link points to a landing page with metadata and data. The third link points to the landing page for the entire data release.
Fees: None.
Technical_Prerequisites:
These data can be viewed with Microsoft Excel or any text reader.
Metadata_Reference_Information:
Metadata_Date: 20250317
Metadata_Contact:
Contact_Information:
Contact_Organization_Primary:
Contact_Organization:
U.S. Geological Survey, Pacific Coastal and Marine Science Center
Contact_Person: PCMSC Science Data Coordinator
Contact_Address:
Address_Type: mailing and physical
Address: 2885 Mission Street
City: Santa Cruz
State_or_Province: CA
Postal_Code: 95060
Contact_Voice_Telephone: 831-427-4747
Contact_Electronic_Mail_Address: pcmsc_data@usgs.gov
Metadata_Standard_Name: Content Standard for Digital Geospatial Metadata
Metadata_Standard_Version: FGDC-STD-001-1998

This page is <https://cmgds.marine.usgs.gov/catalog/pcmsc/DataReleases/ScienceBase/DR_P13B46QX/TN403_SedimentGeochemistry_Metadata.html>
Generated by mp version 2.9.51 on Tue Apr 1 10:12:10 2025